摘要
在分析GB/T18430.11-2007、GB50189-2005以及相关研究文献的基础上,指出我国关于冷水机组综合部分负荷性能系数IPLV的定义无论是表达形式还是其4个权重系数都是错误的。以现有文献资料数据为案例,给出了正确构建IPLV表达式的方法。
based on the analysis of GB/T18430.1-2007, GB50189-2005 and related research literature, the paper points out that our definition of a chiller integrated part load value IPLV in either form of expression or the 4 weight coefficients are wrong. Based on the data of existing literature as a ease, it gives the method to construct the correct IPLV expression.
出处
《江西科技师范大学学报》
2013年第6期91-94,9,共5页
Journal of Jiangxi Science & Technology Normal University