摘要
目的 探讨血细胞分析仪用于血性脑脊液红细胞计数的可行性.方法 收集133份血性脑脊液标本,观察组采用ABX pentra 60血细胞分析仪、对照组采用显微镜传统计数进行红细胞的计数,采用配对t检验方法对检测结果进行统计学分析.结果 对照组和观察组测定的红细胞数分别为916.72×109/L和869.66×109/L,两种方法计数红细胞的结果比较,差异无统计学意义[t=1.091,V=132,P=0.277(双侧)].结论 ABX pentra 60血细胞分析仪与手工镜检方法检测血性脑脊液红细胞结果无统计学差异.
Objective To explore the feasibility of hematology analyzer for the cell counting of hemorrhagic cerebrospinal fluid. Methods 133 hemorrhagic cerebrospinal fluid specimens were collected. Traditional microscope counting was used in the control group and ABX-pentra-60 hematology analyzer was used in the observation group to count the red cells. The data were analyzed using paired t-test statistical analysis. Results The number of red cells was 916.72 × 10^9/L in the control group and was 869.66 × 10^9/L in the observation group, wihtout statistical difference (t= 1.091, V= 132, P=0.277 [bilateral]). Conclusion ABX- pentra-60 hematology analyzer can be use in the cell counting of hemorrhagic cerebrospinal fluid.
出处
《国际医药卫生导报》
2014年第2期259-261,共3页
International Medicine and Health Guidance News
关键词
脑脊液
细胞计数
血细胞分析仪
分析
Hemorrhagic cerebrospinal fluid
Cell counting
Hematology analyzer
Analysis