北外滩白玉兰广场酒店塔楼超高层结构设计 被引量:3

Structural Design of the North Bund Magnolia Plaza Hotel Super High-rise Building
下载PDF
导出
摘要 北外滩白玉兰广场酒店塔楼大屋面高度为171 m,采用了桩端后注浆的钻孔钢灌注桩和3.0 m厚钢筋混凝土筏板,选择了带顶部加强层的型钢混凝土框架—核心筒—刚臂结构的混合结构体系。对于结构的风荷载和地震作用取值、振型信息、风和地震作用下的计算结果进行了介绍,着重阐述了设计中的一些关键问题:中震下性能指标所采取的措施、剪力墙中设置钢骨减小墙体厚度、伸臂桁架和环带桁架的设置以及弹塑性分析。 The North Bund Magnolia Plaza Hotel tower with 171 m height is a high-rise building.Cast-in-site piles with post grouting technology and mat foundation of 3.0 m thickness are adopted.The SRC frame-core-outriggers structural system with strengthened storey is used in this structure.Rudimentary information such as wind loads,earthquake effects,vibration modes,structural responses under wind and seismic loading,was introduced.Some key issues of design were emphasized,including structural measures under moderate earthquakes,steel in shear walls for reducing wall thickness,outriggers and belt trusses,and performing elastoplastic analysis.
作者 杨枫
出处 《结构工程师》 北大核心 2013年第6期1-6,共6页 Structural Engineers
关键词 超高层结构 框架—核心筒—刚臂结构 性能指标 伸臂桁架 弹塑性分析 super high-rise building frame-core-outriggers structural system performance index outriggers elasto-plastic analysis
  • 相关文献

参考文献1

二级参考文献6

  • 1邹昀,吕西林,钱江.上海环球金融中心大厦结构抗震性能研究[J].建筑结构学报,2006,27(6):74-80. 被引量:27
  • 2上海市建设和交通委员会科学技术委员会.上海市超限高层高层建筑工程抗震设防专项审查选编[M].上海,2007.
  • 3中华人民共和国建设部 国家质量监督检验检疫总局.GB50010-2002混凝土结构设计规范[S].北京:中国建筑工业出版社,2002.17.
  • 4中华人民共和国建设部.GB50011-2001建筑抗震设计规范[S].北京:中国建筑工业出版社,2001..
  • 5中华人民共和国建设部.JGJ3-2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
  • 6王亚勇,岳茂光,李宏男,陈洪斌.基于不同性能目标的RC结构抗震设计的效益分析[J].土木工程学报,2008,41(3):37-45. 被引量:21

共引文献83

同被引文献19

引证文献3

二级引证文献20