摘要 目的探讨蓝光滤过型人工晶状体(SN60AT)与染色非球面人工晶状体(AQ-310Ni)在中间视力下视觉对比敏感度及色觉方面的差异。方法选择双眼白内障患者30人共60只眼进行白内障超声乳化联合人工晶体植入术,随机选取一眼植入SN60AT,另一眼植入AQ-310Ni,比较两组的最佳校正视力、瞳孔直径、SPP2色觉检查及对比敏感度。结果在所有亮度条件下,SN60AT组与AQ-310Ni组的最佳矫正视力、瞳孔直径、伪调节等方面比较无统计学差异(P>0.05);在50Lux和20Lux亮度下,AQ-310Ni组的SPP2色觉要优于SN60AT组(P<0.05);在所有亮度条件下,对比敏感度检查中,AQ-310Ni组的对比敏感度要优于SN60AT组(P<0.05)。结论 AQ-310Ni更接近正常年轻人的晶状体折射光谱,在较暗的光线条件下具有更好的视觉质量。
出处 《河北医药》 CAS 2014年第2期231-233,共3页 Hebei Medical Journal
  • 相关文献

参考文献8

  • 1毕宏生.对比敏感度在眼科的临床应用[J].中华眼科杂志,2004,40(9):645-648. 被引量:58
  • 2Schade OH. Optical and photogelectric analog of the eye. J Opt Soc Am, 1956,46:721-739.
  • 3Nepomuceno RL, Boxer Wachler BS, Sato M, et al. Use of large optical zones with LADAR vision laser for myopia and myopia astrigmatism. Ophthalmology ,2003,110 : 1384-1390.
  • 4Ulrich M, Patrick D, Nicola A. Impact of a modified optic design on vis- ual function: Clinical comparative study. J Cataract Refract Surg,2003, 29:652-660.
  • 5Ricci F, Scuderi G, Missiroli F, et al. Low contrast visual acuity in pseudophakic patients implanted with an anterior surface modified. Pro- late intraocular lens. Acta Ophthalmol Scand,2004 ,82 :718-722.
  • 6Rodriguez-Galietero A, Montes-Mico R, Munoz G, et al. Comparison ofcontrast sensitivity and color discrimination after clear and yellow intraoc- ular lens implantation. J Cataract Refract Surg, 2005,31 : 1736-1740.
  • 7Robert C. Acrysof Natural offers retina protection against blue-light am- age. Eyewodd,2003, 8 : 314-318.
  • 8孙政基,谷照斌,市川一夫.黄色人工晶状体.中国实用眼科杂志,2005,23:5-7.

二级参考文献17

  • 1丁传庆,孙葆忱.滤光镜对正常人对比敏感度的影响[J].中国实用眼科杂志,1995,13(2):76-79. 被引量:7
  • 2Campbell FW,Robson JG.Application of fourier analysis to the visibility of gratings.J Physiol,1968,197:551-566.
  • 3Superstein R,Byaner D,Overbury O,et al.Glare disability and contrast sensitivity before and after cataract surgery.J Cataract Refract Surg,1997,23:248-253.
  • 4Adamsons LA,Vitale S,Stark WJ,et al.The association of postoperative subjective visual function with acuity,glare and contrast sensitivity in patients with early cataract.Arch Ophthalmol,1996,114:529-536.
  • 5Rubin GS,Adamtont IA,Stark WJ.Comparion of acuity,contrast sensitivity,and disability glare before and after cataract surgery.Arch Ophthalmol,1993,111: 56-61.
  • 6Ross JE,Bron AJ,Reeves BJ,et al.Contrast sensitivity and visual disability in chronic simple glaucoma.Br J Ophthalmol,1984,68:821-827.
  • 7Howe JW.Electrophysiologically determined contrast sensitivity in patients with ocular hypertension and chronic glaucoma.Doc Ophthalmol,1992,80:31-41.
  • 8Seiler T,Kaemmerer M,Mierdel P,et al.Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism.Arch Ophthalmol,2000,118:17-21.
  • 9Emilio C,Campos,Maria LP,et al.Contrast sensitivity difference between strabismic and anisometropic amblyopia: objective correlate by means of viaual evoked responses.Doc Ophthalmol,1984,50:45-49.
  • 10Kleiner RC,Enger C,Alexander MF,et al.Contrast sensitivity in age-related macular degeneration.Arch Ophthalmol,1988,106:55-57.