低心率及心率变异下前门控CT冠状动脉造影中重叠时间设置的临床研究 被引量:7

Padding Time Setting for Prospective ECG Gating in Computed Tomographic Coronary Angiography:A Clinical Study of Low Heart Rate and Heart Rate Variability
原文传递
导出
摘要 目的采用前瞻性心电门控技术行低心率患者冠状动脉CT成像(CTCA),探讨重叠时间(PT)设置的临床应用价值。方法本研究共选取拟行CTCA检查的患者160例(心率≤55次/min,心率变异≤5次/min),依据患者体重指数选择管电流(270~800mA)、管电压设置为120kV。PT设置范围在0—150ms,每间隔10ms纳入10例患者。绘制受试者工作特征曲线(ROC)推断不同门设置下冠状动脉节段可评估性的切点。采用X2检验比较切点前后冠状动脉节段可评估率差异;分析心率与图像质量、辐射剂量的相关性。结果共有2257支冠状动脉节段参与评分,冠状动脉评分(4.55±0.66)分;ROC曲线显示不同胛设置下冠状动脉节段可评估性的切点为40ms,〈40ms与t〉40ms者冠状动脉节段可评估率比较:96.2%%VS99.2%(X2=23.751,P=0.000),差异具有统计学意义;PT设置与图像质量、辐射剂量呈正相关。结论在低心率及心率变异度下前瞻性心电门控技术可将PT设置修改为40ms可获得满足诊断的图像,同时降低辐射剂量。 Objective To evaluate value of padding time setting in coronary artery computed tomographic angiography with prospectively gated axial (PGA) CT technique at low heart rate ( ~〈65 beats per minute, bpm). Methods 160 pa- tients with heart rates(HR) (54.51 ± 6.66)bpm( range :42 -- 65 bpm) was evaluated in this retrospective study. All pa- tients used PGA CT technique (tube voltage was 120 kV and tube current tailored to BMI). The patient enrolled in subset by every 10 ms with the padding time(PT) setting(0 - 150 ms). The PT of ≤40 ms and 〉40 ms was compared with per- eentage of assessable coronary artery segments by Chi-Square test. To evaluate the relationship between PT and image quali- ty or radiation dose by spearman or pearson correlation analysis. Results There were 2257 coronary artery segments to be evaluated. The mean image quality score was 4.55 + 0.66. Below a PT of 40ms, as determined by receiver operator charac- teristic(ROC) curve, 3.8% of coronary segments were non-diagnostic compared with 0.8% with PT of 〉 40 ms( X2 = 23. 751 ,P = 0. 000). The relationship between PT and image quality or radiation dose was positive correlation. Conclu- sion PGA coronary CT angiography using 40ms padding time settings could offer assessable image quality at low HR and HRv.
出处 《临床放射学杂志》 CSCD 北大核心 2014年第1期117-120,共4页 Journal of Clinical Radiology
基金 内蒙古财政厅科研项目(编号:NC20080018) 内蒙古高等学校科学研究项目(编号:NJZY07091)
关键词 体层摄影术X线计算机 冠状动脉 图像处理 辐射剂量 Tomography,X-ray computed Coronary artery Image processing Radiation dose
  • 相关文献

参考文献3

二级参考文献11

共引文献149

同被引文献71

  • 1余晓锷,卢广文.CT系统的性能参数[M].CT设备原理、结构与质量保证.北京:科学出版社,2005:107-116.
  • 2Maffei E, Martini C, De Crescenzo S, et al. Low dose CT of the heart: A quantum leap into a new era of cardiovascular imaging[J]. Radiology Medical, 2010, 115: 1179-1207.
  • 3Sung WK, Young JK, Jaemin S, et al. Coronary artery calcium scoring does not add prognostic va]ue to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease[J]. Radiology. 259: 92-99.
  • 4Earls JP, Berman EL, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose[J]. Radiology, 2008, 246: 742-753.
  • 5Engel L, Ferencik M, Liew GY, et al. Ultra-low dose cardiac CT angiography at 80 kV using second generation dual-source CT: Assessment of radiation dose and image quality[J]. Journal of Medical Diagnosis Method, 2012, 1: 1-7.
  • 6Komatsu S, Kamata T, Imai A, et al. Coronary computed tomography angiography using ultra-low-dose contrast media: Radiation dose and image quality[J]. International Journal of Cardiovascular Imaging, 2012, 59(13sl): E1357-E1357.
  • 7Guidelines on Radiation Dose to the Patient[RJ. European Commission. guropean gulaellnes on quality criteria for computed tomography. Report EUR 16262 EN. Office for Official Publication of the European Communities, Luxembourg. http://www, drs. dk/guidelines /ct/quality/index. htm. Accessed 20 January 2010.
  • 8Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: Report of the ad hoc committee for grading of coronary artery discase, council on cardiovascular surgery, american heart association[J]. Circulation, 1975, 51($4): 5-40.
  • 9ICRP Publication 60:1990 recommendations of the international commission on radiological protectionEM]. Annals of the ICRP 21(1-3). Oxford: Pergamon Press, 1991.
  • 10Viteri-Ramirez G, Garcia-Lallana A, Simon-Yarza I, et al. Low radiation and low-contrast dose pulmonary CT angiography: Comparison of 80kVp/60mL and lOOkVp/80mL protocols[J]. Clinical Radiology, 2012, 67: 833-839.

引证文献7

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部