300MW等级CFB锅炉机组采用单列风机配置的研究与应用 被引量:1

Study and Application of Single Set Configuration of Fans in 300 MW CFB Boiler Unit
下载PDF
导出
摘要 以往,国内大中型燃煤发电机组烟风系统主要辅机(三大风机、空预器等)均按双系列设置,即均按2×50%容量配置。本文针对项目特点,对风机单列设置的风机选型、可靠性、经济性及系统设置方面进行了研究,拓宽了锅炉烟风系统主要辅机配置方案的设计思路。而工程实践也证明了本文在风机设置方面的探索是正确的。 In the past, the main auxiliary equipment of the flue gas system (three main fans, air heater, etc.) is double set in the domestic' fossil fired power plant design, that is installing two(2) 50% capacity equipment. Base on the charaeteristic of the project, the paper studies the fans selection, reliability, economy and system design of the single set fans, which has widened the view of the main auxiliary equipment set design in flue gas system. The projeet practice has proved exploration of the paper in the fans set is cozTect
出处 《风机技术》 2013年第6期78-82,共5页 Chinese Journal of Turbomachinery
关键词 单列风机 CFB锅炉 风机选型 烟风系统 节能 single set fans CFB boiler fans selection flue gas system energy saving