三种眼压计对维族和汉族大学生眼压测量值比较 被引量:1

Comparative analysis of intraocular pressure in Uyghur and Han students by three types of tonometer
下载PDF
导出
摘要 目的:比较Goldmann眼压计、非接触式眼压计与Schiotz眼压计对维吾尔族、汉族大学生眼压测量值结果。方法:横断面研究。分别采用Goldmann眼压计、非接触式眼压计与Schiotz眼压计测量维吾尔族、汉族大学生眼压。比较两族整体间、同族不同性别间、不同眼别间三种眼压计测得的眼压值。结果:相同眼压计对维吾尔族及汉族大学生眼压测量值差异有统计学意义(P<0.05);相同眼压计对同族不同性别间眼压测量值差异无统计学意义(P>0.05);相同眼压计对不同眼别间眼压测量值差异无统计学意义(P>0.05),汉族学生比维吾尔族学生眼压测量值高(P<0.05),非接触式眼压计比Goldmann眼压计眼压测量值偏高(P<0.05),非接触式眼压计比Schiotz眼压计眼压测量值要小(P<0.05)。结论:同一眼压测量仪对同族不同性别间及不同眼别间无差异,汉族学生比维吾尔族学生眼压测量值高,Schiotz眼压计眼压值测量结果显著高于非接触式眼压计,而非接触式眼压计眼压测量值高于Goldmann眼压计。 AIM : To compare the intraocular pressure measurements of the college students of Uyghur and Han by Goldmann tonometer, non- contact tonometer and Schiotz tonometer. METHODS: This cross-sectional study measured the intraocular pressure of college students of Uyghur and Han with Goldmann tonometer, non-contact tonometer and Schiotz tonometer respectively; comparison was made in the intraocular pressure measurements between the two races, between the two genders in the same race, and between the right and left eyes by three different ophthalmotonometers. RESULTS: The differences in intraocular pressure measurements by the same tonometer between college students of Uyghur and Han were statistically significant (P〈0.05); the differences in the measurements between different genders in one race by the same tonometer were not statistically significant (P〉0.05) ; the differences in the measurements between the right and left eyes with the same tonometer were not statistically significant (P 〉 0.05) ; the intraocular pressure measurements of college students of Han were higher than that of college students of Uyghur ( P〈 0. 05 ) ; measurements by non - contact tonometer were higher than those by Goldmann tonometer ( P〈 0. 05) ; measurements by non - contact tonometer were lower than those by Schiotz tonometer (P〈 0. 05). CONCLUSION: There are no differences in the measurements between the two genders and between the right and left eyes by the same tonometer; the measurements of college students of Han are higher than those of college students of Uyghur; measurements by Schiotz tonometer are significantly higher than those by non-contact tonometer; measurements by non-contact tonometer are higher than those by Goldmann tonometer.
出处 《国际眼科杂志》 CAS 2014年第2期297-299,共3页 International Eye Science
关键词 GOLDMANN眼压计 非接触式眼压计 SCHIOTZ眼压计 眼压 Goldmann tonometer non- contacttonometer Schiotz tonometer intraocular pressure
  • 相关文献

参考文献23

二级参考文献91

共引文献130

同被引文献6

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部