摘要 冷却塔的空气动力特性是确保冷却塔高效的设计关键。本文采用Fluent软件,对内陆核电重要厂用水系统鼓风式机械通风冷却塔在不同塔型条件下的空气动力特性进行了数值模拟计算,获得了冷却塔塔型与冷却塔阻力及填料断面风速分布均匀性的关系。计算结果表明,填料安装高度对鼓风式机械通风冷却塔整塔阻力影响不大,但会影响填料断面上风速分布均匀性,填料安装高度越低,风速分布越均匀,填料阻力系数越小影响越明显;出口收缩段的高度越高,整塔阻力越小,风速分布越均匀。 With the Fluent-3D, this paper conducts the simulation and calculation of the aerodynamic char- acteristics of the forced draft mechanical cooling tower in the important water system of the inland nuclear power plant, and obtains the relationship between the tower shape and the resistance. The results show that the height of the fill does not much affect the resistance of the tower,but it affects the velocity distribution on the fill section. The lower the fill height is, the more uniform the velocity distribution is. The higher the height of the convergent section of the outlet is, the less the resistance is, and the more uniform the velocity distribution is.
出处 《中国水利水电科学研究院学报》 2013年第3期206-209,共4页 Journal of China Institute of Water Resources and Hydropower Research
关键词 鼓风式冷却塔 塔型 阻力系数 风速均匀性 forced draft mechanical cooling tower tower shape resistance coefficient the uniformity ofthe velocity distribution
  • 相关文献

参考文献6

二级参考文献20

  • 1张遐龄,杨旭,李向群,安亦然.火电厂空冷平台换热的数值模拟[J].水动力学研究与进展(A辑),2005,20(z1):874-880. 被引量:33
  • 2贺益英.关于火、核电厂循环冷却水的余热利用问题[J].中国水利水电科学研究院学报,2004,2(4):315-320. 被引量:37
  • 3陈胜利.江苏双良空调设备股份有限公司直接空冷凝汽器系统性能试验报告[R].西安:西安热工研究院有限公司,2006.
  • 4陈胜利.钢制椭圆管矩形翅片空冷元件传热及阻力性能试验研究报告[R].西安:西安热工研究院有限公司,2006.
  • 5赵文升,王松岭,高月芬,崔凝.直接空冷系统中热风回流现象的数值模拟和分析[J].动力工程,2007,27(4):487-491. 被引量:26
  • 6Detlev G Kroger. Air- cooled heat exchangers and cooling tower: thermal- flow performance and design (Volume Ⅱ )[M]. 1996.
  • 7Meyer C J, D G Kroger. Air - cooled heat exchanger inlet flow losses. Applied thermal engineering[J]. 2001,21.. 771 - 786.
  • 8张健.朔州市格瑞特实业有限公司煤矸石综合利用发电项目2×135Mw发电机组直接空冷系统技术协议[z].上海:江苏双良空调设备股份有限公司,2006.
  • 9Detlev G Kroger. Air- cooled heat exchangers and cooling tower: thermal- flow performance and design (Volume Ⅰ )[M]. 1996.
  • 10US NRC. Generic enviromnental impact statement for license renewal of nuclear plants [S]. Main Report. NUREG-1437,Volume 1, Revision 1. Washington DC: US NRC, 2009.

共引文献67

同被引文献41

引证文献8

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部