期刊文献+

柱下端局部采用FRC材料钢筋混凝土柱的承载力分析

Bearing Capacity Analysis of the Column with Fiber Reinforced Concrete in Bottom Region
下载PDF
导出
摘要 为了改善钢筋混凝土柱的变形能力和损伤容限,在其下端局部采用纤维增强混凝土(FRC)代替普通混凝土,设计了6根剪跨比为3、柱内配置较少箍筋的钢筋混凝土柱试件,进行了拟静力试验。试验结果表明,这种柱为弯曲屈服后的剪切破坏,具有较好的变形能力和损伤容限;局部使用FRC材料可以减少约束箍筋和抗剪箍筋用量。根据试验结果,建立了考虑截面受拉区FRC受拉作用的压弯承载力计算方法以及斜截面受剪承载力计算公式,其中斜截面受剪承载力计算公式的计算值与试验值比较吻合。 In order to improve the deformation capacity and damage tolerance of the reinforced concrete columns ,six reinforced concrete column specimens with fiber reinforced concrete (FRC ) in the bottom region instead of ordinary concrete were tested under reversed cyclic lateral loading .The specimens’ shear span ratio is three and its configuration of stirrups are relatively few . T he test results show that these columns exhibit shear failures after the longitudinal reinforcement yielding , and they have better deformation capacity and damage tolerance .The column with FRC in the bottom region can reduce the amount of constraint stirrup and shear stirrup . According to the test results , bending bearing capacity calculation method considering FRC tension action and shear capacity formula were established .The shear capacity calculated by the adopted formula are in good agreement with the test results .
出处 《土木建筑与环境工程》 CSCD 北大核心 2014年第1期38-43,共6页 Journal of Civil,Architectural & Environment Engineering
基金 国家自然科学基金(51278402 51078305)
关键词 纤维增强混凝土柱 损伤容限 承载力 fiber reinforced concrete column damage tolerance bearing capacity
  • 相关文献

参考文献7

二级参考文献44

  • 1中华人民共和国建设部,国家质量技术监督检验检疫总局.GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 2Bilington A L. Damage-Tolerant Cement-Based Materials for Performance Based Earthquake Engineering Design: Research Needs [ G ]// Fracture Mechanics of Concrete Structures. IA - FraMCos ,2004:53 - 60.
  • 3Fischer G, Li V C. Effect of Matrix Ductility on Deformation Behavior of Steel Reinforced ECC Flexural Members Under Reversed Cyclic Loading Conditions [ J ]. ACI Structural Journal, 2002, 99(6):781 -790.
  • 4Li V C. On the Shear Behavior of ECC [J]. J Adv Cem Based Mater, 1994,1 (3) :142 - 1491.
  • 5Maallej M J. Hight-Velocity Impact Resistance of Hybrid-Fiber ECC [ C ]//Proceedings, FraMCos 5. 2004 : 1051 - 1058.
  • 6Wang S, Li V C. Polyvinyl Alcohol Fiber Reinforced Engineered Cementitious Composites: Material Design and Performances [ C ]// Proceedings of Int' 1 Workshop on HPFRCC in Structural Applications. Honolulu, Hawaii, USA. 2005:23 - 26.
  • 7Alexander M G, Magee B J. Durability Performance of Concrete Containing Condensed Silica Fume [ J]. Cement and Concrete Research, 1999(29) :917 -922.
  • 8Martinola G, Baeuml M F, Wittmann F H. Modified ECC by Means of Internal hnpregnation [ J ]. J of Advanced Concrete Technology, 2004, 12 (2) :207 - 212.
  • 9Li V C, Lepeeh M, Wang S, et al. Development of Green ECC for Sustainable Infrastructure Systems [ C ] // Proc. , Int ' 1 Workshop on Sustainable Development and Concrete Technology, Beijing, China: Published by Iowa State Univ., 2004:181 - 192.
  • 10Song G, Zijl G V. Tailoring ECC for Commercial Application [ C ] // Proceedings of BEFIB, Varenna, Lake Como, Italy. 2004 : 1391 - 1400.

共引文献140

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部