摘要 上海光源恒流注入模式需建立辐射剂量硬件联锁。剂量联锁系统以PLC为基础,采用一主站四从站的现场总线布局,通过语句表编程实现逻辑综合,并具有故障记录功能。程序采用字逻辑将状态输入与设定屏蔽位图进行比较,逐个模块地检查有无累积剂量超限输入和瞬时剂量超限输入,综合后经断开延时形成累积剂量联锁输出和瞬时剂量联锁输出。程序通过双字逻辑比较,得到新近发生的故障位置和故障时间,形成故障记录。故障记录功能有助于参与联锁探测器的故障定点诊断和维护。 Radiation dose interlock is necessary for top-up operation in Shanghai Synchrotron Radiation Facility (SSRF) .The radiation dose interlock system was based on a programmable logic controller (PLC) .On PROFIBUS ,the system was built up with an S7-300 master and 4 slaves .With DWORD logic , the inputs were compared with the input masks module by module to tell if there were trip signals .The trip signals and the status of all the detectors were logically synthesized and off-delayed for two interlock outputs .The trip events were located and recorded together with date and time . The record function is proved to be useful for disorder diagnostics of the radiation dose detectors .
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2014年第1期175-178,共4页 Atomic Energy Science and Technology
关键词 恒流注入模式 辐射剂量联锁 故障记录 PLC PROFIBUS top-up operation radiation dose interlock PLC PROFIBUS error record
  • 相关文献

参考文献10

  • 1ZHAO Z T, YIN Y L, LI H H, et al. Progress towards top-up operation at SSRF[C]// Proceedings of IPAC 2011. San Sebastian, Spain: JACoW, 2011.
  • 2EMERY L, BORLAND M. Top-up operation experience at the Advanced Photon Source[C]// Proceedings of the 1999 Particle Accelerator Conference. New York: JACoW, 1999.
  • 3KALANTARI B, KORHONEN T, LUDEKE A, et al. Enhancement of top-up operation at the Swiss Light Source[C]// Proceedings of EPAC 2004. Lucerne, Switzerland: JACoW, 2004.
  • 4OHKUMA H. Top-up operation in light sources [C]// Proceedings of EPAC08. Genoa, Italy: JACoW, 2008.
  • 5ASANO v, TAKAGI T. Radiation safety issues for top-up operation at SPring-8 [J]. Radiation Measurements, 2007, 41(S2): 236-241.
  • 6WALKER R r , BARTOLINI R, BONNER r , et al. Preparation for top-up operation at DIAMOND[C]// Proceedings of EPAC08. Genoa, Italy: JACoW, 2008.
  • 7SHEN L R, CHEN J F, CHEN G H, et al. Safety interlock implementation of top-up operation in the SSRF control system [C]// Proceedings of IPAC2012. New Orleans, Louisiana, USA: JACoW, 2012.
  • 8李宗强,伏明灯,王桂玲,朱小龙,苏有武.兰州重离子研究装置的辐射监测系统[J].核电子学与探测技术,2004,24(3):292-294. 被引量:3
  • 9李俊刚,李铁辉,陈志兴.BEPCⅡ数字化辐射防护平台研究及应用[J].核电子学与探测技术,2010,30(9):1144-1149. 被引量:14
  • 10王晓飞,胡跃明,李明龙,胡任威.HI-13串列加速器辐射防护联锁系统[J].原子能科学技术,2008,42(B09):267-269. 被引量:3

二级参考文献12

  • 1郑华智.兰州重离子研究装置(HIRFL)的辐射防护[J].辐射防护,1993,13(5):331-336. 被引量:1
  • 2汤树明,那相印,吴靖民.用可编程控制器实现BEPC安全联锁系统——PLC在测控系统中的应用[J].计算机自动测量与控制,1996,4(4):8-11. 被引量:2
  • 3李铁辉,吴靖民,刘列夫.北京正负电子对撞机人身安全联锁系统的改进[J].辐射防护,1997,17(1):47-54. 被引量:1
  • 4汤月里 李建平 等.BEPC工作场所辐射监测系统[J].核电子学与探测技术,1988,4:244-244.
  • 5李铁辉,陈志兴,张清江.数字化辐射防护[C].全国放射性流出物和环境监测与评价研讨会论文汇编,2003.
  • 6Ted de Castro.Radiation Safety for the Design and Operation of Particle Accelerators[S].ANSIN43.1,2005.
  • 7National Council of Radiological Protection and Measuroments (NCRP),Radiation Protection for Particle Accelerator Facilities[R].NCRP Report No.144,2003.
  • 8中国科学院高能物理研究所技术安全室.北京正负电子对撞机(BEPC)辐射防护设计报告[R].1984.
  • 9中华人民共和国国家质量监督检验检疫总局.GB18871-2002,电离辐射与辐射源安全基本标准[S].北京:中国标准出版社,2003.
  • 10Li Jianping, et al. Neutron energy response of a modified ANDERSSON-BRAUN rem counter. Radiation [J]. Protection Dosimetry, 1996, 67 (3):(1996).

共引文献17

同被引文献22

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部