摘要
A parallel system with two active components and a cold standby unit is studied in this paper. The two simultaneously working components are dependent and the copula function is used to model their dependence. An explicit expression is obtained for the mean time to failure of the system in terms of the copula function and marginal lifetime distributions in two different cases. As an application,numerical calculations are presented corresponding to two different copula functions and marginal lifetime distributions.
A parallel system with two active components and a cold standby unit is studied in this paper. The two simultaneously working components are dependent and the copula function is used to model their dependence. An explicit expression is obtained for the mean time to failure of the system in terms of the copula function and marginal lifetime distributions in two different cases As an application, numerical calculations are presented corresponding to two different copula functions and marginal lifetime distributions.
基金
Funded by the Natural Science Foundation of China under grant No.71101095