锰的微分电位溶出分析法研究及应用 被引量:2

Research and application of digestion analysis of differential potential of Mn
下载PDF
导出
摘要 利用同位镀汞膜代替预镀贡膜 ,通过标准实验研究了微分电位溶出分析方法测定微量锰的实验条件。结果表示该方法测定锰重现性好 ,灵敏度高 ,相性相关系数为 0 .9996,标准回收率为98%~ 10 4 % ,对具体的空气样品和水样实际分析 。 The experimental conditions are studied in the article,which involve determining micromanganese with the analytical method of differential potential ligature in a standard experiment by replacing mercury preplating film with isotope mercury plating film.The result shows that this method has a good reproduction and a high sensitivity in determining manganese.The relation coefficient is 0.9996,and the recovery ratio is 98%~104%,The result is satisfactory in analyzing air sample and water sample with the method.
出处 《河南城建高等专科学校学报》 2000年第4期46-48,共3页 Journal of Henan Urban Construction Junior College
关键词 微分电位溶出分析法 测定 空气样品 水样 Mn differential potential digestion analytical method
  • 相关文献

参考文献4

  • 1中国预防医学科学院卫生与职业病防治研究所.车间空气监测检验方法(第三版)[M].北京:人民卫生出版社,1990..
  • 2中国预防医学科学院环境卫生监测所.环境空气质量监测检验方法[M].北京:中国科学技术出版社,1991.158-166.
  • 3秦文华.电位溶出法分析法基本原理及应用[M].郑州:河南科学技术出版社,1993.315-317.
  • 4张子刚.管理统计学[M].武汉:华中理工大学工商管理学院,1997..