阐述了对GB 50057—2010《建筑物防雷设计规范》相关条文的不同意见,指出滚球半径的选取应视被保护物的重要性而定。说明了利用避雷针引雷、避雷线拦截雷电流是解决露天堆场防雷的有效方法,可为类似设计提供参考。
The different opinions on the relevant provisions of the GB 50057-2010 Code for Design Protection of Structures Against Lightning were stated. Suggestions that selection of ball radius should consider the importance of the protected object were proposed. The lightning arrester and lighting shield line was effective methods for solving the open yard lightning protection. It could provide references for similar design.
出处
《现代建筑电气》
2014年第1期44-45,52,共3页
Modern Architecture Electric
关键词
露天堆场
防雷
滚球半径
open yard
lightning protection
ball radius