摘要
为解决灌缝胶流动值测试装置在实际操作中试验条件不统和测量结果不准确的问题,有针对性地对原流动值测试装置的设计进行了改进,提出了定位测量工作台。介绍定位测量工作台每个部分的功能及其工作原理,后给出了使用该装置测量灌缝胶时正确的使用方法及注意事项。
In order to solve the problem, that test conditions are not uniform and test results are inaccurate, of flow value testing device of sealants in using, the design of flow value testing device was improved, and a positioning measurement device was put forward. The function and working principle of every part were introduced, and the usage and precautions during testing by the new device were given at last.
出处
《筑路机械与施工机械化》
2014年第2期68-70,共3页
Road Machinery & Construction Mechanization
关键词
灌缝胶
流动值
测试装置改进
定位测量装置
sealant
flow value
improvement of testing device
positioning measurement device