杨树浦发电厂于2010年年底实施了关停,在原有厂区内建设分布式能源站,具有很好的环保、人文、和谐、创新等新意,凸显出百年燃煤电厂关停后,坚持走绿色、低碳、可持续发展道路。介绍了构建燃气分布式能源站的边界条件、冷热电负荷的确定;分析了冷热电负荷的特点,优化了设备选型配置及相关技术参数;给出了系统优选组合下的安全、可靠、经济运行的策略。
Yangshupu Power Plant was shut down in the end of 2010, distributed energy sources station will be built at the original factory, it has new ideas on environmental protection,humanity.harmony and innovation and adhere to the road of green, low carbon and sustainable development after the coal-fired power plant with one century's history has been shut down. This paper introduces constructing boundary conditions of distributed energy sources station and the determination of cooling and heating electrical load, analyses cooling and heating electrical load" characteristic, optimizes equipment selection and allocation and correlating parameter, obtains a safe, reliable and economical operation strategy at the system preferred combination.
出处
《电力与能源》
2014年第1期59-62,共4页
Power & Energy
关键词
分布式能源站
冷热电负荷
技术分析
三联供运行策略
Distributed energy sources station
Cooling and heating power load
Technical analysis
Triplegeneration operation strategy