期刊文献+

除氧剂在天然气处理厂锅炉给水中应用效果分析 被引量:3

Analysis on Application Effect of Deoxidizers in Boiler Feed Water in Natural Gas Treatment Plant
下载PDF
导出
摘要 通过对苏里格某天然气处理厂目前使用的除氧剂无水亚硫酸钠、联氨及二甲基酮肟除氧效果进行了分析对比,实验结果表明:无水亚硫酸钠除氧效果最好,加量为40 mg/L即可完全去除原水中的溶解氧,但后续会对锅炉产生不利影响。从安全、环保综合考虑,建议采用二甲基酮肟为除氧剂,加量为60 mg/L。 Deoxidization effects of deoxidizers (anhydrous sodium sulfite, hydrazine and dimethyl ketone oxime) currently used a natural gas treatment plant were analyzed and compared. The experimental results show that: the deoxidization effect of anhydrous sodium sulfite is the best; when its dosage is 40 mg/L, dissolved oxygen in the raw water can be completely removed, but it will be harmful to boiler.From comprehensive consideration of safety and environmental protection, dimethyl ketone oxime should be used as deoxidizer, its suitable dosage is 60 mg/L.
出处 《辽宁化工》 CAS 2014年第1期28-30,共3页 Liaoning Chemical Industry
关键词 除氧剂 无水亚硫酸钠 联氨 二甲基酮肟 deoxidant anhydrous sodium sulfite hydrazine DMKO
  • 相关文献

参考文献6

二级参考文献36

共引文献51

同被引文献35

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部