摘要 Background As for the patients with coronary arteriosclerosis, the presence of ischemic myocardial survival is significant for the treatment and prognosis. Gated 13N-NH3 and 18SF-FDG PET/CT imaging provides myocardial perfusion, metabolism and cardiac function which can valuate myocardial viability accurately and noninvasively. Methods Four pigs were subjected to bilateral internal mammary artery Y-bypass operation in operating room. The pigs under the anesthetized state were sent to PET center when the operation finished. Then 13N-NH3 gated-PET/CT and 18F-FDG gated-PET/CT were performed. Results The myocardial perfusion and myocardial metabolism is well-distributed of left ventricular wall. The motion of the wall was normal. The ejection function was greater than 50%. Conclusion Gated-PET/CT can be used for noninvasive evaluation of myocardial perfusion, myocardial metabolism and left ventricle function. Background As for the patients with coronary arteriosclerosis, the presence of ischemic myocardial survival is significant for the treatment and prognosis. Gated 13N-NH3 and 18SF-FDG PET/CT imaging provides myocardial perfusion, metabolism and cardiac function which can valuate myocardial viability accurately and noninvasively. Methods Four pigs were subjected to bilateral internal mammary artery Y-bypass operation in operating room. The pigs under the anesthetized state were sent to PET center when the operation finished. Then 13N-NH3 gated-PET/CT and 18F-FDG gated-PET/CT were performed. Results The myocardial perfusion and myocardial metabolism is well-distributed of left ventricular wall. The motion of the wall was normal. The ejection function was greater than 50%. Conclusion Gated-PET/CT can be used for noninvasive evaluation of myocardial perfusion, myocardial metabolism and left ventricle function.
出处 《South China Journal of Cardiology》 CAS 2013年第4期266-271,共6页 岭南心血管病杂志(英文版)
基金 supported by National Science & Technology Pillar Program during the 12th Fiveyear Plan Period(No.SQ2011SF12C03081) Key Program for International S&T Cooperation Projects of China(No.2010DFA32660)
关键词 TOMOGRAPHY emission computed POSITRON gated myocardial imaging tomography emission computed positron gated myocardial imaging
  • 相关文献

参考文献11

  • 1Di Carli MF, Dorbala S, Meserve J, et al. Clinical my- ocardial perfusion PET/CT. J Nucl Med 2007,48: 783- 793.
  • 2Jadvar H, Parker JA. Clinical PET and PET/CT. London 2005 : 69-85.
  • 3Kanayama S, Matsunari I, Hirayama A, et al. Assess- ment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emis- sion tomography in patients with coronary artery disease. Circ J 2005, 69:177-182.
  • 4Willemsen AT, Siebelink HJ, Blanksma PK, Paans AM. Automated ejection fraction determination from gated myocardial FDG-PET data. J Nucl Cardiol 1999, 6: 577-582.
  • 5Dou KF, Yang MF, Yang YJ, et al. Myocardial ^18F-FDG uptake after exercise-induced myocardial ischemia in patients with coronary artery disease. J Nucl Med 2008,49:1986-1991.
  • 6Saab G, Dekemp RA, Ukkonen H, et al. Gated fluorine 18 fluorodeoxyglucose positron emission tomography: determination of global and regional left ventricular func- tion and myocardial tissue characterization. J Nucl Car- diol 2003, 10: 297-303.
  • 7Khorsand A, Graf S, Frank H, et al. Model-based anal- ysis of electrocardiographygated cardiac ^18F-FDG PET images to assess left ventricular geometry and contractile function. J Nucl Med 2003, 44: 1741-1746.
  • 8Blankstein R, Di Carli. MF Integration of coronary anatomy and myocardial perfusion imaging. Nat Rev Cardiol 2010, 7: 226-236.
  • 9Pereztol-Valdrs O, Candell-Riera J, Santana-Boado C, et al. Correspondence between left venlricular 17 my- ocardial segments and coronary arteries. Eur Heart J 2005, 26: 2637-2643.
  • 10Khorsand A, Graf S, Eidherr H, et al. Gated Cardiac 13N-NH3 PET for Assessment of Left Ventricular Vol- umes, Mass, and Ejection Fraction: Comparison with Electrocardiography-Gated ^18F-FDG PET. J Nucl Med 2005, 46: 2009-2013.