导出
摘要 通过半连续式实验考察了臭氧投加量和初始pH对剩余污泥臭氧处理的影响.结果表明,随着臭氧投加量的增加,污泥溶解率增加,有机质、氮、磷等物质释放到污泥液相中;最佳臭氧投加量控制在约150 mg·g-1(以SS计),污泥溶解率可达约26%;污泥臭氧减量应在初始pH中性或偏碱性条件下进行,此时污泥溶解率较高,有利于有机质和氮的溶出.臭氧处理后污泥回流至生物处理系统对微生物的生物活性、COD和TN的去除效果无显著影响,但由于系统中无剩余污泥排放,导致TP的去除效果明显下降.臭氧处理后污泥上清液的Ca(OH)2除磷实验发现,较高的钙磷摩尔比对上清液除磷有利;当其值控制在10.0左右时,TP的去除率大于80%. Semi-continuous mode experiments were adopted to examine the effects of ozone dose and initial pH on the sludge reduction by ozone. The results indicated that, as the ozone dose increased, the sludge solubilization ratio increased and the organic compounds, nitrogen and phosphorus were gradually released into the water phase of sludge. The optimal ozone dose was around 150 mg'g -1 ( in SS), at which the sludge solubilization ratio could reach about 26%. An initial neutral or alkaline pH value favored the sludge reduction, under which a high sludge solubilization ratio was obtained and the release of organic compounds and nitrogen was enhanced. The recycling of ozonated sludge to biological treatment system had no obvious impact on the microbial activity and the removal effieiencies of COD and TN, while the removal efficiency of phosphorus declined obviously because of the zero discharge of excess sludge from the biological treatment system. The experimental results of phosphorus removal from ozonated sludge supernatant by Ca (OH) 2 indicated that a high Ca/P molar ratio was beneficial for phosphorus removal; when this ratio was controlled at about 10.0, the removal efficiency of TP could reach more than 80%.
出处 《环境科学学报》 CAS CSCD 北大核心 2014年第2期363-369,共7页 Acta Scientiae Circumstantiae
基金 西门子(中国)有限公司资助项目(污泥源头减量工艺研究) 国家自然科学基金项目(No.21277160 51138009)~~
关键词 污泥减量 臭氧 除磷 污水处理厂 sludge reduction ozone phosphorus removal wastewater treatment plant
  • 相关文献

参考文献20

  • 1Abraham F I, Md Abul H S. 2007. Formatiort of pyrazines in hydroxyacetaldehyde and glyeine nonenzymatie browning Maillard reaction: A computational study [ J]. Food Chemistry, 103 (4) : 1208-1216.
  • 2Ahn K H, Park K Y, Maeng S K, et al. 2002. Ozanatian of wastewater sludge for reduction and recycling [ J 1. Water Science and Technology, 46(10): 71-77.
  • 3Bohler M, Siegrist H. 2004. Partial ozonation of activated sludge to reduce excess sludge, improve denitrification and control scumming and bulking [J]. Water Science and Technology, 49 (10) : 41-49.
  • 4Bougrier C, Albasi C, Delgens J P, et al. 2006. Effect of ultrasonic, thermal and ozone pre-treatments on waste activated sludge solubilization and anaerobic biodegradability [ J ]. Chemical Engineering and Processing, 45 ( 8 ) : 711-718.
  • 5Chu L B, Yan S T, Xing X H, et al. 2009. Progress and perspectives of sludge ozonation as a powerful pretreatment method for minmimization of excess sludge production [ Jl. Water Research, 43 (7) : 1811-1822.
  • 6Dytczak M A, Londry K, Siegrist H, et al. 2006. Extracellular polymers in partly ozonated return activated sludge: impact on flocculation and dewaterability [ J ]. Water Science and Technology, 54 ( 9 ) : 155-164.
  • 7傅涛,肖琼,成杨.2010.污泥处理处置市场的困惑与徘徊[EB/OL].2013-06-25.中国固废网:http://news.solidwaste.con.cn/view/id_43551.
  • 8寇青青,朱世云,覃宇,汤正泽,荣春,侯天骏,杜晶.臭氧氧化联合A/A/O工艺污泥减量的可行性[J].净水技术,2012,31(4):102-104. 被引量:5
  • 9Lee J W, Cha H Y, Park K Y,et al. 2005. Operational strategies for an activated sludge process in conjunction with ozone oxidation for zero excess sludge production during winter season [ . Water Research, 39(7) : 1199-1204.
  • 10Saktaywin W, Tsuno H, Nagare H, et al. 2005. Advanced sewage treatment process with excess sludge reduction and phosphorus recovery [J]. Water Research, 39(5): 902-910.

二级参考文献50

  • 1曾晓岚,龙腾锐,丁文川,许龙,邹璐.低能量超声波辐射提高好氧污泥活性研究[J].中国给水排水,2006,22(5):88-91. 被引量:19
  • 2闫怡新,刘红.低强度超声波强化污水生物处理机制[J].环境科学,2006,27(4):647-650. 被引量:18
  • 3宋铁红,高艳娇,王佳佳,黄继国.臭氧化污泥减量技术对出水水质的影响[J].净水技术,2006,25(3):53-55. 被引量:2
  • 4梁鹏,黄霞,钱易,杨乃鹏.3种生物处理方式对污泥减量效果的比较及优化[J].环境科学,2006,27(11):2339-2343. 被引量:19
  • 5[3]Tiehm A.,Nickel K.,Zellhorn M.,et al.Ultrasonic waste activated sludge disintegration for improving anaerobic stabilization.Water Research,2001,35 (8):2003~2009
  • 6[5]Sangave P.C.,Gogate P.R.,Pandit A.B.Ultrasound and ozone assisted biological degradation of thermally pretreated and anaerobically pretreated distillery wastewater.Chemosphere,2007,68(1):42~50
  • 7[6]Sheng G.P.,Yu H.Q.Characterization of extracellular polymeric substances of aerobic and anaerobic sludge using three-dimensional excitation and emission matrix fluorescence spectroscopy.Water Research,2006,40 (6):1233~1239
  • 8[7]APHA,AWWA,WEF.Standard Methods for the Examination of Water and Wastewater,20th ed.Americal Public Health Association,Washington DC,USA,1998
  • 9[8]Lowry O.H.,Rosebrough N.J.,Farn A.,et al.Protein measurement with the folin phenol reagent.Journal of Biological Chemistry,1951,193:265~275
  • 10[10]Ding W.C.,Li D.X.,Zeng X.L.,et al.Enhancing excess sludge aerobic digestion with low intensity ultrasound.Journal of Central South University of Technology,2006,13(4):408~411

共引文献151