给水加氧处理在超超临界1000MW机组的应用 被引量:3

Application of feed water oxygenated treatment on ultra supercritical 1000 MW unit
下载PDF
导出
摘要 徐州电厂超超临界1000MW机组投产后及时采用了给水加氧处理技术,介绍了1号机组给水加氧转换过程、水汽指标的变化情况。加氧处理技术实施后水汽系统含铁量显著降低,精处理混床运行周期延长,加药量减少,效果显著,提高了机组运行的经济性和安全性。 Feed water oxygenated treatment is adopted timely after production of ultra supercritical JOOOMW unit in Xuzhou power plant. Conversion process of feed water oxygenated treatment,variation of water quality are in- troduced. Water vapor system iron content is significantly reduced,operation peration period of mixed bed is ex- tended and dosage is reduced afer implementation of feed water oxygenated treatment technology. The effect is remarkable. The economy and security for the unit operation is obviously improved.
作者 袁方
出处 《电力科技与环保》 2014年第1期33-35,共3页 Electric Power Technology and Environmental Protection
关键词 超超临界 1000MW机组 给水加氧 含铁量 ultra supercritical l 000 MW unit feed water iron content
  • 相关文献

参考文献5

二级参考文献23

  • 1李志刚,陈戎.火电厂锅炉给水加氧处理技术研究[J].中国电力,2004,37(11):47-52. 被引量:43
  • 2DL/T912-2005,超临界火力发电机组水汽质量标准[S].
  • 3曹杰玉,王二福,刘玮,宋敬霞,石秋生.DL/T677-2009发电厂在线化学仪表检验规程[s],中华人民共和国国家能源局,2009.
  • 4Quadri G, Scolari P V, Scalari G P, et al. Combined water treatment (CWT) in oncethrough boilers: ENEL experience [C]. International Water Conference 51, Pittsburgh, PA, 1990.
  • 5DL/T805.1-2002.火电厂汽水化学导则第1部分:直流锅炉给水加氧处理导则[S].
  • 6DL/T794-2001.火电厂锅炉化学清洗导则[S].
  • 7Dooley R B, Larkin B, Webb L, et al. Oxygenated treatment for fossil plants [C]. International Water Conference 53,Pittsburgh, PA,1992.
  • 8DL/T805.1-2002,火电厂汽水化学导则第一部分:直流锅炉给水加氧处理导则[S].
  • 9VGB-R450Le 1988, VGB Guidelines for Boiler Feedwater, Boiler Water,Steam of Steam Generators with A Permissible Operating Pressure >68 ba[S ].
  • 10T H McCloskey, R B Dooley, W P McNaughton. Turbine Steam Path Damage: Theory and Practice [ M ].EPRI, 1999.

共引文献48

同被引文献107

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部