摘要
广东粤电云河发电有限公司配套SG-1036/17.5-M4506型循环流化床(CFB)锅炉,投运后存在一些问题,通过燃烧调整试验,取得了良好的效果。锅炉整体床温水平降低、厂用电率降低,锅炉效率提高,运行经济性显著提高,同时延长了锅炉安全稳定运行周期。
Guangdong Yudean Yunhe Power Station Co. , Ltd. is matched SG - 1036/17.5 - M4506 type circulating fluidized bed boiler ( CFB), there are some problems after the operation, good results is achieved by the combustion adjustment test. and The overall level of boiler bed temperature decreased, plant electricity rate decreased, the boiler efficiency is improved, the economy improved significantly, while extending the safe and stable operation cycle of the boiler cycle.
出处
《应用能源技术》
2014年第2期31-33,共3页
Applied Energy Technology
关键词
CFB锅炉
燃烧调整
厂用电率
床温
CFB boiler
Combustion adjustment
Plant electricity rate
Bed temperature