年龄相关性白内障合并浅前房患者白内障术后屈光状态研究 被引量:28

Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber
原文传递
导出
摘要 目的 研究年龄相关性白内障合并浅前房患者白内障术后屈光状态特点及白内障术前前房深度与术后屈光状态的相关性.方法 前瞻性对照研究.2010年10月至2012年1月于北京大学人民医院就诊的年龄相关性白内障患者共68例(90只眼),根据Pentacam眼前节分析系统测量的前房深度将入选病例分为对照组28例(34只眼),浅前房组40例(56只眼).应用IOL Master测量眼轴长度和角膜曲率,应用SRK-T公式计算IOL度数.白内障术后1个月及3个月复测屈光度数、前房深度并行眼部全面检查.采用SPSS13.0软件建立数据库,两组比较采用独立样本t检验,采用二元相关与回归进行相关性分析.结果 术后1个月对照组及浅前房组屈光度数误差分别为(-0.39 ±0.62)D及(+0.73±0.26)D,两组之间差异有统计学意义(=3.67,P=0.00).术后3个月对照组及浅前房组屈光度数误差分别为(-0.37±0.62)D及(+0.79±0.28)D,两组之间差异有统计学意义(P=0.00,t=3.33).浅前房组中,前房深度越浅,术后屈光度数误差越大(r1个月=-0.57,r3个H=-0.61,P=0.00).结论 年龄相关性白内障合并浅前房患者术后存在远视漂移,且术前前房越浅,远视漂移程度越大. Objective To evaluate the characteristics of postoperative refractive status in agerelated cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperativerefractive status. Methods Prospective case-control study. Sixty-eight cases(90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases(34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentaeam system. Axial length and keratometer were measured by IOL Master and intraoc.ular lens power was calculated using SRK/ T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSSI3.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. Results The postoperative refractive deviation atl month were ( -0. 39 ± 0. 62 )D in control group and ( + 0. 73 ± 0. 26 )D in shallow anterior chamber group respectively which present statistical significance between the two groups ( P = 0. 00, t = 3.67 ) ; the postoperative refractive deviation in 3 month was( -0.37 ±0.62)D in control group and ( +0.79 ±0.28)D in shallow anterior chamber group seperatively which present statistical significance between the two groups ( P = 0. 00, t = 3.33 ). In shallow anterior chamber group, with the shallowerof ACD, the greater of refractive deviation (P = 0. 00, r 1 month = - 0. 57, r 3months = - 0. 61 ). Conclusion Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.
出处 《中华眼科杂志》 CAS CSCD 北大核心 2014年第2期84-88,共5页 Chinese Journal of Ophthalmology
关键词 白内障摘除术 前房 屈光 Cataract extraction Anterior chamber Refraction, ocular
  • 相关文献

参考文献17

  • 1汤欣,宋慧.白内障术后视觉质量的综合评估[J].中华眼科杂志,2012,48(4):379-382. 被引量:16
  • 2Falkner-Radler CI, Benesch T, Binder S. Accuracy of preoperative biometry in vitreetomy combined with cataract surgery for patients with epiretinal membranes and maealar holes: results of a prospective controlled clinical trial [ J ]. J Cataract Refract Surg, 2008,34 : 1754-1760.
  • 3Su WW, Chen PY, Hsiao CH, et al. Primaryphacoemulsifieation and intraocular lens implantation for acute primary angle-closure [ J]. PLoS One.2011. 6 : e20056.
  • 4裴雪婷,鲍永珍,黎晓新.晶状体密度测量在年龄相关性白内障诊断中的价值探讨[J].眼科研究,2009,27(1):49-54. 被引量:19
  • 5He M, Huang W, Zheng Y, eL al. Anterior chamber depth in elderly Chinese: the Liwan eye study [ J ]. Ophthahnology, 2008, 115 : 1286-1290.
  • 6陈放,盛耀华,李增琦.SRK-Ⅱ公式与第三代人工晶体计算公式的比较[J].中国实用眼科杂志,2000,18(3):139-142. 被引量:33
  • 71,adas JG, Stark WJ. hnproving cataract surgery Refiraetive Outcomes[ J]. Ophthahnology,2011,118:1699-1700.
  • 8Olsen T, Nielsen PJ. Immersion versus contact technique in the measurement of axial length by uhrasound [ J ]. Aeta Ophthahuol, 1989,67 : 101-102.
  • 9Haigis W. Pseudophakic correction factors tor optical hiometry [ J]. Graefes Arch Chin Exp Ophthalmol,2001,239 :589-598.
  • 10Kiss B, Findl O, Menapace R, el al. Refi'aetive outeome of cataract surgery using partial coherence intefferometry and uhrasound biometry: clinical feasibility study of a eummercial prototype II[ J ]. J Cataract Refract Surg,2002,28:230-234.

二级参考文献37

  • 1曾明兵,刘奕志,柳夏林.角膜屈光手术后人工晶状体度数的计算及其影响因素[J].国际眼科纵览,2007,31(2):82-85. 被引量:3
  • 2Chylack LT,Wolfe JK,Singer DM, et al. The lens opacities classification system Ⅲ[ J ]. Arch Ophthalmol, 1993,111 : 831 - 836
  • 3Klein BEK, Klein R, Linto KLP, et al. Assessment of cataracts from photography in the Beaver Dam Eye Study [ J ]. Ophthalmology, 1990,97: 1428 - 1433
  • 4Taylor HR, West SK. The clinical grading of lens opacities [ J ]. Aust New Zealand J Ophthalmol, 1989,17 : 81 - 86
  • 5Hockwin D, Dragomirescu V,Laser H. Measurements of lens transparency or its disturbance by densitometric image analysis of Scheimpflug photographs [ J ]. Graefe ' s Arch Clin Exp Ophthalmol, 1982, 219 : 255 - 262
  • 6Baez KA, Orengo S, Gandham S, et al. Intraobserver and interobserver reproducibility of the Nidek EAS-1000 Anterior Eye Segment Analysis System [ J ]. Ophthalmic Surg, 1992,23 ( 6 ) : 426 - 428
  • 7Sasaki H,Kawakami Y, Ono M, et al. Localization of cortical cataract in subjects of diverse races and latitude [ J ]. Invest Ophthalmol Vis Sci, 2003,44: 4210 -4214
  • 8Auffarth GU, Borkensein AF, Ehmer A. Scheimpflug and topography systems in ophthalmologic diagnostics [ J ]. Ophthalmologe, 2008,105 ( 9 ) :810 -817
  • 9Barkana Y, Gerber Y ,Elbaz U, et al. Central comeal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [ J ]. J Cataract Refract Surg, 2005,31:1729 - 1732
  • 10Lackner B, Schmidinger G, Pieh S, et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and Uhrasound [ J ]. Optom Vis Sci,2005,82:892 - 899

共引文献68

同被引文献207

引证文献28

二级引证文献113

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部