期刊文献+

性能化机械排烟设计方法在剧场观众厅中的应用 被引量:2

Performance-based design of mechanical exhaust in theater auditorium
下载PDF
导出
摘要 剧场观众厅一般为高大空间,且不划分防火分区,参照规范设计的机械排烟量较大。采用性能化分析方法来开展某剧场观众厅的排烟设计,先通过美国NFPA92B中的产烟率计算公式确定机械排烟量,再利用典型场景下的烟气模拟和人员疏散模拟验证所设计排烟量的安全性。结果表明,采用性能化机械排烟设计方法能大大降低剧场观众厅的机械排烟量。 Theater auditorium is generally tall and large space, and does not diVide the fire compartment, the mechanical exhaust smoke volume designed according to the codes will be too large. Designs the smoke exhaust system of a theater auditorium with the performance-based analysis method, calculates the mechanical exhaust smoke volume by formula of smoke production rate in the U. S. NFPA92B firstly, and then verifies the security of the mechanical exhaust smoke volume with the smoke and personnel evacuation simulation under typical scenario. The result shows that the performance-based mechanical exhaust design method can greatly reduce the mechanical exhaust smoke volume of the theater auditorium.
作者 肖春花
出处 《暖通空调》 北大核心 2014年第2期43-45,25,共4页 Heating Ventilating & Air Conditioning
关键词 剧场观众厅 机械排烟量 性能化设计 高大空间 theater auditorium, mechanical exhaust smoke volume, performance-based design, talland large space
  • 相关文献

参考文献2

二级参考文献6

  • 1GBJ16-1987.建筑设计防火规范.[S].,..
  • 2GB50045-1995.高层民用建筑设计防火规范.[S].,(2001年版)..
  • 3National Fire Protection Association,Guide for Smoke Manangement Systems in Malls,Atria,and Large Areas (NFPA92B), 2000.
  • 4National Fire Protection Association, NFPA204, Guidefor Smoke and Heat Venting(NFPA204),2000.
  • 5DGJ08-88-2000.民用建筑防排烟技术规程.[S].,(2001年版)..
  • 6NFPA92B(2000 Editon),Guide for Smoke Manage ment Systems in Malls,Atria, and Large Areas[s].

共引文献10

同被引文献9

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部