期刊文献+

固相萃取-高效液相色谱法检测中成药中人工合成色素 被引量:1

Detection of Synthetic Pigments in Chinese Patent Drugs by Solid Phase Extraction-HPLC
下载PDF
导出
摘要 目的:建立检测中成药中人工合成色素的固相萃取-高效液相色谱(SPE-HPLC)分析方法。方法:样品利用聚酰胺固相萃取柱净化和富集后进行HPLC分析。采用资生堂C18色谱柱,以甲醇和0.02mol·L-1醋酸铵为流动相进行梯度洗脱,检测波长:508nm,柱温:30℃,进样量:10μl。结果:合成色素线性范围均为0.005~0.200μg(r=0.9999),回收率分别为97.6%(RSD=1.3%,n=6)、97.0%(RSD=1.4%,n=6)和99.5%(RSD=1.4%,n=6)。结论:该方法操作简单,结果准确可靠,重复性好,适用于中成药中人工合成色素的检测。 Objective: To establish a method for detecting synthetic pigments in Chinese patent drugs by solid phase extraction-HPLC(SPE-HPLC). Methods: Purified with SPE and concentrated, the sample was separated on a SHISEIDO C18 column with 0.02 mol·L-1 ammonium acetate and methanol mixed solution as the mobile phase with gradient elution at the flow rate of 1.0 ml·min-1, the detection wavelength of 508nm, column temperature of 30℃,and the injection volume of 10μl. Results:The linear range of the synthetic pigments was 0.005-0.200 μg(r=0.999 9), and the average recovery was 97.6%(RSD=1.3%,n=6),97.0%(RSD=1.4%,n=6) and 99.5%(RSD=1.4%,n=6), respectively. Conclusion:The proposed method is simple, reliable and reproducible, and especially suitable for the detection of synthetic pigments in Chinese patent drugs.
出处 《中国药师》 CAS 2014年第2期201-204,共4页 China Pharmacist
关键词 固相萃取 高效液相色谱法 中成药 合成色素 Solid phase extraction HPLC Chinese patent drugs Synthetic pigments
  • 相关文献

参考文献5

二级参考文献26

共引文献86

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部