阐述了转炉炼钢氧压控制系统的故障原因及处理方法。通过分析研究 ,找出了系统不稳定因素 ,合理选择PID调节参数 ,提高了控制系统的稳定性。
Through cause analysis of breakdown of oxygen pressure regulation system in converter steelmaking,a shaky factor is discovered.When reasonble PID regulation parameters are selected,the stabilization of control system is improved greatly.
出处
《江西冶金》
2000年第6期28-31,共4页
Jiangxi Metallurgy