期刊文献+

CEREC 3不同光学印模在后牙种植修复中的临床研究 被引量:6

A clinical study of different optical impression in implant restoration of posterior tooth using CEREC 3
原文传递
导出
摘要 目的:比较CEREC 3直接法光学印模和间接法光学印模在后牙种植修复中临床效果的差别。方法:选取80颗后牙种植CEREC全瓷冠修复病例,其中实验组40例使用CEREC直接法制取光学印模,对照组40例使用间接法制取光学印模,然后根据印模数据分别制作全瓷冠并口内粘接。修复后追踪观察2年,调查患者的满意度,并按照改良的USPHS标准进行临床评价。结果:实验组和对照组总体满意度分别为100.0%和97.5%,在外形,表面质地和颜色上无明显差别,在边缘适合性方面分别为90.0%和100.0%,两者比较有统计学差异(P<0.05)。结论:在后牙种植CEREC全瓷冠修复时,间接光学印模优于直接光学印模。 Objective:To compare differences of the clinical effect from two different optical impression (direct and indirect) in implant restoration of posterior tooth using CEREC 3.Method:80 implants were restored using Cerec all-ceramic crowns.The experimental group of 40 implants using Cerec were made directly from the optical impression,the control group of 40 patients were used indirect preparation of optical impression.Finished followed for 2 years,patient satisfaction were investigated and clinical effect were evaluaed in accordance with the modified USPHS criteria.Result:The experimental and control groups were 100.0 % and 97.5 % on overall satisfaction.There was no significant difference in shape,surface texture and color.Two groups were respectively 90.0 % and 100.0 % on marginal fit,a significant difference.Conclusion:The indirect optical impression is better than direct optical impression when CEREC all-ceramic crowns can be used as dental implant restoration.
出处 《临床口腔医学杂志》 2014年第2期109-112,共4页 Journal of Clinical Stomatology
基金 武汉市青年科技晨光计划项目(201050231091)
关键词 椅旁美学陶瓷修复系统 CAD CAM 牙种植 CEREC CAD / CAM dental implants
  • 相关文献

参考文献11

  • 1Allen KL,Schenkel AB, Estefan D. An overview of the ('EREC 3 CAD / CAM system [J]. Gen Dent, 2004, 52 (3) : 234-235.
  • 2Fasbinder l)J. Clinical performance of chairside CAD / CAM restora- tions J]. J Ann Dent Assoe, 2006, 137:22-3 I.
  • 3王林虎,郭家平.CEREC椅旁CAD/CAM诊室技术25年的研究进展[J].国际口腔医学杂志,2012,39(1):124-127. 被引量:15
  • 4Neal Patel. Integrating three-dimensional digital technologies tk)r comprehensive implant dentistry [J]. J Am Dent Assoe,2010, 141: 20-24.
  • 5Wittneben JG, Wrighi RF, Weber ttP,et al. A systematic review of the clinical performance of CAD / CAM single-tooth reslorations [J] lnt J Prosthodont, 2009, 22 (5) : 466-471.
  • 6Roggendorf M J, Kunzi B, Eberl J, et al. Seven-year clinical perlbrm- anee of CEIEC-2 all-ceramic CAD/CAM restnrations placed within deeply destroyed teeth [J]. Clin Oral Investig, 2012, 16 (5): 1413-1424.
  • 7李蓉,蒋滔,王贻宁,程祥荣.Cerec CAD/CAM全瓷嵌体和高嵌体3年临床研究[J].口腔医学研究,2005,21(6):664-666. 被引量:29
  • 8Schmitter M, Seydler BB. Minimally invasive lithium disilicate cera- mic veneers fabricated using chairside CAD / CAM: A clinical report [J]. J Prosthet Dent, 2012, 107 (2) : 71-74.
  • 9Da Costa JB, Pelogia F, Hagedorn B, et al. Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D [J]. Oper Dent, 2010, 35 (3) ." 324-329.
  • 10Keshvad A, Hooshmand T, Asefzadeh F, et al. Marginal gap, internalfit,and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques [J]. J Prosthodont, 2011,20 (7) : 535-540.

二级参考文献17

  • 1Fasbinder DJ. Clinical performance of chairside CAD/ CAM restorations[J]. J Am Dent Assoc, 2006, 137(Suppl): 22S-31S.
  • 2Fradeani M, Redemagni M. An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: A retro- spective study[J]. Quintessence Int, 2002, 33 (7):503- 510.
  • 3Chen HY, Hiekel R, Seteos JC, et al. Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns[J]. J Prosthet Dent, 1999, 82(4) :458-475.
  • 4Bindl A, Richter B, Mormann WH. Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry[J]. Int J Prosthodont, 2005, 18 (3) : 219-224.
  • 5Mehl A, Ender A, Mormann W, et al. Accuracy testing of a new intraoral 3D camera[J]. Int J Comput Dent, 2009, 12(1) : 11-28.
  • 6Gedosev M. The perfect companion: Ceree 3D software upgrade V3.40[J]. Int J Comput Dent, 2009, 12 (1):59- 70.
  • 7Mehl A, Blanz V, Hickel R. A new mathematical proeess for the calculation of average forms of teeth[J]. J Prosthet Dent, 2005, 94(6) : 561-566.
  • 8Mehl A, Blanz V. New procedure for fully automatic occlusal surface reconstruction by means of a biogenetic tooth model[J]. Int J Comput Dent, 2005, 8 (1):13-25.
  • 9Schneider W. No compromises the new CEREC MC XL and inLab MC XL milling machlnes[J]. Int J Comput Dent, 2007, 10(1) : 119-126.
  • 10Fasbinder DJ, Dennison JB, Heys D, et al. A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: A two-year report[J]. J Am Dent Assoc, 2010, 141 (Suppl 2) : 10S-14S.

共引文献41