期刊文献+

3D虚拟模体设计软件的开发 被引量:3

Development of a Software for 3D Virtual Phantom Design
原文传递
导出
摘要 本文应用面向对象编程技术开发了一个适用于医学物理研究的三维虚拟模体的设计软件。该软件命名为Magical Phantom(MPhantom),由三维可视化编辑模块和虚拟CT扫描模块构成。用户使用MPhantom可以快捷的实现复杂3D虚拟模体的可视化设计,并且将虚拟模体输出为符合DICOM 3.0协议的CT数据。MPhantom的模体设计功能和CT数据输出功能通过了实际的应用场景测试,是一个界面友好,功能强大的工具软件。该软件将极大的方便放射治疗中的蒙特卡罗剂量模拟以及X射线影像重建算法等的研究工作。 In this paper, we present a 3D virtual phantom design software, which was developed based on object-oriented programming methodology and dedicated to medical physics research. This software was named Magical Phan tom (MPhantom), which is composed of 3D visual builder module and virtual CT scanner. The users can conveniently construct any complex 3D phantom, and then export the phantom as DICOM 3.0 CT images. MPhantom is a userfriendly and powerful software for 3D phantom configuration, and has passed the real scene's application test. MPhantom will accelerate the Monte Carlo simulation for dose calculation in radiation therapy and X ray imagingre construction algorithm research.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2014年第1期76-80,共5页 Journal of Biomedical Engineering
关键词 3D虚拟模体 虚拟CT扫描 蒙特卡罗剂量模拟 影像重建算法 3D virtual phantom virtual CT scanner Monte Carlo dose simulation image reconstruction algorithm
  • 相关文献

参考文献16

  • 1MA C M,JIA:-.I(; S B, PAWLICKI T. et al. A quality assur?ance phantom for lMRT dose verification[J]. Phys Med Bi- 01,2003,48(5) :561-572.
  • 2YOO S, YIN F F. Dosimetric feasibility of cone-beam cr?based treatment planning compared to CT-based treatment planning[J]. IntJ Radiat Oncol Bioi Phys , 2006, 66 (11) : 1553-1561.
  • 3OUYANG L, SOLBERG T, WAN(;J. Noise reduction in low-dose cone beam CT by incorporating prior volumetric im?age information[J]. Med Phys, 2012, 39(5): 2569-2577.
  • 4PETERJ,JASZCZAK R, COL[MAN R. Composite quad?ric-based object model for SPECT Monte-Carlo simulation[C]/ /45th Annual Meeting of the Society of Nuclear Mcdi cine, Toronto: 1998: 121P.
  • 5PETERJ, GILLAND D R,J ASZCZAK RJ, ct al. Four-di?mensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems[n. IEEE Trans Nucl Sci, 1999,46(6): 2211-2217.
  • 6SEGARS W p, XCAT T B. The evolution of 4-D computer?ized phantoms for imaging research[J]. Proceedings of the IEEE, 2009, 97(]2): 1954-1968.
  • 7SEGARS W r. STURGEON G, MENDONCA S, et al. 4D XCA T phantom for multi modality imaging research[J]. Med Phys , 2010, 37(9): 4902-4915.
  • 8SOHN M, SOBOTTA B, ALBER M. Dosimetric treatment course simulation based on a statistical model of deformable organ motion[J]. Phys Med Biol. 2012, 57(12): 3693-3709.
  • 9ROLAND T, HALES R, MCNUTT T, et al. A method for deriving a 4 D-interpolaled balanced planning target fur mubile tumor radiotherapy[J]. Med Phys, 20 I 2, 39 ( I): 11;j20S.
  • 10CAON M. Voxel-based computational models of real human anatomy: a review[J]. Radiat Environ Biophys , 2004, 42 (4): 229-235.

同被引文献19

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部