摘要 内置钢板深梁剪力墙是由钢管混凝土柱、柱间钢板深梁、混凝土墙体及其连接构件组成。对5个1/5缩尺的该组合剪力墙模型进行了低周反复荷载试验。试验分两阶段进行,第一阶段试验研究位移角小于1/50试件的抗震性能,第二阶段试验研究第一阶段损伤试件修复后的抗震性能,修复采用剪力墙边框钢管间两侧贴焊薄钢板的方法。分析了各试件修复前后的破坏特征、滞回特性、承载力、刚度退化、位移延性、耗能性能。结果表明:内置钢板深梁剪力墙的钢管混凝土柱、钢板深梁、混凝土墙体及连接构件相互作用,协同受力,具有良好的抗震性能;变形特征具有阶段性,在混凝土和部件连接界面损伤前与整体剪力墙变形接近,在连接界面损伤滑移后与带竖缝剪力墙接近。 A shear wall with concealed steel plate deep beams contains CFST columns, steel plate deep beams, RC walls and connecting components. Low cyclic loading tests on seismic behavior of five 1/5 scaled composite shear wall specimens were carried out. The loading was divided into two stages Loading stage one focused on the seismic behavior of specimens before the drift of 1/50, while stage two focused on the seismic behavior of specimens repaired after the first stage, and the repair was carried out by welding thin steel plates between the steel tubular columns. Failure characteristics, hysteretic characteristics, load-bearing capacity, stiffness degradation, ductility, and the energy dissipation of specimens before and after repair were studied. Study shows that: the CFST columns, steel plate deep beams, RC walls and the corresponding connecting components can collaborate closely and exhibit a good seismic behavior; the deformation behavior differs at different stages, in which the deformation is close to that of entire shear walls before the concrete wall cracking, and close to shear wall with vertical slit after the slippage between the steel tube and concrete wall.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2014年第3期68-76,共9页 Journal of Building Structures
基金 国家自然科学基金项目(51178010) 北京市自然科学基金项目(8122004) 北京市教委科技创新平台项目(PXM2011-014204-09-000090 PXM2011-014204-09-000127)
关键词 钢管混凝土 钢板深梁 剪力墙 损伤修复 拟静力试验 抗震性能 concrete filled steel tube (CFST) steel plate deep beam shear wall damage repair quasi-static test seismic behavior
  • 相关文献

参考文献10

二级参考文献41

  • 1汪大绥,陆道渊,黄良,王建,徐麟,朱俊.天津津塔结构设计[J].建筑结构学报,2009,30(S1):1-7. 被引量:42
  • 2李国强,张晓光,沈祖炎.钢板外包混凝土剪力墙板抗剪滞回性能试验研究[J].工业建筑,1995,25(6):32-35. 被引量:65
  • 3侯蕾,孙彤,郝际平,董子建.十字加劲肋钢板剪力墙低周反复荷载的试验[J].钢结构,2006,21(2):12-16. 被引量:26
  • 4ZHAO QIUHONG, ABOLHASSAN ASTANEH-ASL. Cyclic behavior of traditional and innovative composite shear walls[ J]. Joural of Structural Engineering,2004,130(2) :271-285.
  • 5ABOLHASSAN ASTANEH-ASL. Seismic behavior and design of composite steel plate shear walls [ J ]. Steel tips, Structural Steel Educational Council,2002 : 1-49
  • 6R PARK, M J N PRIESTLEY, W D GILL. Ductility of square-confined concrete columns[J]. ASCE, 1982(4)
  • 7GB50152-1992混凝土结构试验方法标准[S].北京:中国建筑工业出版社,1992.
  • 8JGJ101-1996,建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997
  • 9Astaneh-asl A, Zhao Q H. Cyclic behavior of steel shear wall systems [C]//Proceedings-Annual Stabili- ty Conference, Structural Stability Research Council, Seattle : Structural Stability Research Council, 2002. 21-36.
  • 10Caccese V, Elgaaly M. Experimental study of thin steel-plate shear walls under cyclic load[J].Journal of Structural Engineering, 1993, 119 (2) : 573-587.

共引文献228

同被引文献38

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部