摘要
以某水力发电厂一起发电机组励磁系统失磁引起的故障处理为例,介绍了故障发生的概况,综合分析了故障原因及排除措施,总结了该故障的处理方法及预防的关键点。
Taking one field loss failure occurred at the generator excitation system of a hydropower plant as exam- ple, the author introduced the basic facts of this failure, analyzed the causes and repair measures, and summarized the treatment methods and prevention measures of this kind of faults.
出处
《广西水利水电》
2014年第1期54-57,共4页
Guangxi Water Resources & Hydropower Engineering
关键词
发电机组
失磁故障
检查与试验
保护定值
处理方法
Turbine generator unit
field loss failure
check and test
protection setting value
treatment method