摘要 本文对理想核脉冲信号和实际探测器输出信号分别进行了计算机模拟仿真与分析,总结了不同成形时间的核脉冲信号的数字梯形成形参数的确定方法。在高计数率场合时提高了有效测量计数率,消除了部分脉冲的堆积并减少了系统死时间。同时,采用256点和512点数字三角成形方法测试了Si-PIN半导体探测器的性能,并与模拟电路成形方法进行了对比测试。测试结果表明,脉冲数字成形处理方法提高了探测器计数率和分辨率。 The computer simulation and analysis were carried out for the ideal nuclear pulse signal and the actual detector output signals ,and the determination method of digital trapezoidal shape parameter for different nuclear pulse shaping time was summarized . At high count rate measurement occasion , the effective count rate is increased ,some pile-up pulses are eliminated and the accumulation of dead time of the system is reduced .Meanwhile ,Si-PIN semiconductor detector performance was tested by 256 points and 512 points digital triangle forming methods and the analog circuit forming methods for comparative tests . Test results show that the pulse forming treatment method increases the count rate performance and the resolution of detector .
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2014年第2期352-356,共5页 Atomic Energy Science and Technology
基金 863计划资助项目(2012AA061804) 国家自然科学基金资助项目(41204133) 四川省科技支撑计划资助项目(2013SZ0109)
关键词 核脉冲信号 数字成形 堆积脉冲 nuclear pulse signal digital shaping pile-up pulses
  • 相关文献

参考文献8

二级参考文献42

  • 1肖无云,魏义祥,艾宪芸.多道脉冲幅度分析中的数字基线估计方法[J].核电子学与探测技术,2005,25(6):601-604. 被引量:16
  • 2邱晓林,方国明,弟宇鸣,许鹏.核辐射脉冲幅度分析的基线卡尔曼滤波估计[J].原子能科学技术,2007,41(3):375-377. 被引量:5
  • 3张谦,景占荣.一种过程噪声自适应调节的卡尔曼滤波算法[J].电子测量技术,2007,30(5):18-20. 被引量:13
  • 4[1]Sim(o)es J B,Correia C M B A.Nucl Instr Meth in Phys Res,1999,A422:405-410
  • 5[3]14-Bit,40 MSPS/65 MSPS A/D Converter AD9244.http://www.analog.com/UploadedFiles/Data_Sheets/AD9 244.pdf
  • 6[4]Cardoso J M,Sim(o)es J B,Correia C M B A.Nucl Instr Meth in Phys Res,2004,A522:487-494
  • 7Simoes J B, Correia C M B A. Nucl Instr Meth in Phys Res, 1999, A422:405-410.
  • 8Performance of digital signal processors for gamma spectrometry. Application Note, Canberra Industries,http:∥www. canberra.com/pdf/Literature/a0338.pdf.
  • 9Vo D T, Russo P A, Sampson T E. Comparisons Between Digital Gamma-Ray Spectrometer (DSPec) and Standard Nuclear Instrumentation Methods (NIM) Systems,LA- 13393-MS, http:∥www. ortec-online.com/pdf/losalamospaper. pdf.
  • 10Veljko R. Nucl Instr Meth, 1972, 99:525-539.