期刊文献+

蒸发冷却空调技术在西安地区适用时间的探讨 被引量:2

The Applicability Time of Evaporative Air Conditioning Technology in Xi 'an
下载PDF
导出
摘要 规定了两个不同室内状态点下蒸发冷却空调技术的适用标准。通过西安地区典型气象年夏季的统计数据与2012年夏季的实际采集数据的对比分析,得出了采用蒸发冷却空调技术制取冷风与冷水两种产出介质下不同的适用时间。冷风式蒸发冷却空调技术的适用时间约占夏季总时间的50%左右,冷水式蒸发冷却空调技术的适用时间约占夏季总时间的40%左右。 It is prescribed by the applicable standards of evaporative cooling under the two different indoor state points. Compared the summer statistics of typical meteorological year with the summer actual collection of data of in 2012 in Xi'an, it shows applicable time which can use the evaporative air conditioning technology. The applicable time of product air accounts for about 50% of the summer total time. And the applicable time of product water accounts for about 40% of the summer total time.
出处 《建筑热能通风空调》 2013年第6期42-45,共4页 Building Energy & Environment
基金 陕西省科技统筹创新工程计划项目(2011KTCQ01-10)
关键词 蒸发冷却 适用时间 中等湿度地区 气象数据 evaporative cooling, applicability time, moderate humidity areas, meteorological data
  • 相关文献

参考文献8

二级参考文献33

共引文献200

同被引文献8

引证文献2

二级引证文献4