摘要 为了使沈阳北部污水厂二级出水达到回用水质,在中试条件下采用污泥回流高效絮凝工艺对其进行深度处理。实验中优化了高效絮凝工艺中的反应强度(G值)、污泥回流比、混凝剂和助凝剂的投药量等工艺运行参数;并考察各种运行条件下的处理效果。实验结果表明,采用污泥回流高效絮凝工艺处理沈阳北部污水厂二级出水效果良好,出水COD≤30 mg/L、浊度≤0.9 NTU、色度≤29度、ρ(TP)≤1 mg/L、ρ(NH3-N)≤10 mg/L,均达到了回用标准。中试条件下的最佳运行参数:污泥回流量在低温低浊工况下为40 L/h,在常温常浊工况下为30 L/h;G值为18.9 s-1;PAC投加量30 mg/L;助凝剂阳离子PAM RT 2300投加量0.45 mg/L。 In order to ensure the quality of second-class effluent in Shenyang north sewage treatment plant meet the level of water quality standard for the reuse of recycling water, the high effective flocculation craft was used for advanced treatment of this effluent in a pilot-scale test. The reacting intensity (G value), sludge return ratio, coagulant and coagulant aid dosage of the high effective flocculation system were optimized, and the treatment effect of the system under different conditions was also investigated. The results show that, the high effective flocculation craft applied in the treatment of the second-class effluent from Shenyang north sewage treatment plant is effective. After treated by high effective flocculation craft, the effluent quality was reaching the expected target: COD ≤30 mg/L, turbidity ≤0.9 NTU, chroma ≤29, p(TP)≤ 1 mg/L, and p(NH3-N)≤10 mg/L. The optimal operation parameters in the pilot-scale test are as follows: sludge recycle flow rate at low temperaatre and low turbidity conditions for 40 L/h, in normal temperature and turbidity conditions for 30 L/h, G value is 18.9 s^-1, the dosage of PAC was 30 mg/L, and the coagulant cationic PAM RT 2300 dosage is 0.45 mg/L.
作者 陈越 张琳
出处 《水处理技术》 CAS CSCD 北大核心 2014年第3期84-86,90,共4页 Technology of Water Treatment
基金 黑龙江省科技攻关项目(E201052) 中央高校基本科研业务费专项资金资助项目(HEUCF130219) 国家自然科学基金(51209053)
关键词 城市污水 深度处理 高效絮凝 污泥回流 urban sewage advanced treatment high effective flocculation sludge reflux
  • 相关文献

参考文献8

  • 1许嘉炯,雷挺,沈裘昌,郑志民,查人光,陈群,朱海涛.嘉兴石臼漾水厂扩容工程的设计和调试运行[J].给水排水,2006,32(5):1-5. 被引量:23
  • 2B Jimenez, A Chavez, C Hemandez. Altemative treatment for wasterwater destined for agricultural use [J].Wat Sci Teeh., 1999,40 (4-5):355-362.
  • 3周志伟.污泥回流强化混凝处理低温低浊水试验研究[D].北京:北京工业大学.2012.
  • 4A D Gottfried, K H Shepard, M E Walsh. Impact of recycling filter backwash water on organic removal in coagulation-sedimentation processes[J].Water Res.,2008(42):4683-4691.
  • 5L H Sun, M Lv, Y L Yang, et al. Enhanced treatment of water with low turbidity: Combination effects of permanganate, PAM and recycled sludge [J].Joumal of Harbin Institute of Technology(New Series),2009:863 -868.
  • 6X H Guan, G H Chen, C Shang. Reuse of water treatment works sludge to enhance particulate pollutant removal from sewage [J]. Water Res.,2005(39):3433-3440.
  • 7付昆明,李冬,朱兆亮,张杰.呼延水厂低温低浊水的絮凝试验研究[J].中国给水排水,2008,24(11):39-42. 被引量:11
  • 8黄正杰,张玉先,缪丽英,张立东.活化硅酸助凝剂在给水处理中的应用研究[J].给水排水,2009,35(S2):63-68. 被引量:10

二级参考文献12

共引文献41

同被引文献15

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部