摘要
对安钢7号高炉空料线停炉操作进行总结:停炉前做好准备工作,停炉过程中前期采用大风量、高风温,中后期控制好风压、风量和炉顶打水,使炉顶温度控制在350℃~500℃之间,成功地将料线降到风口中心线以下.同时对炉役末期炉体严重破损的高炉停炉技术加以归纳总结,使得空料线停炉技术得到进一步完善和发展.
In Angang No. 7 blast furnace air feed line shutdown operation were summarized : prepare before stopping the furnace, large air volume, high wind temperature the shutdown process, in the late control pressure, air and water at top, the top temperature controlled at 350 -500 DEG C, successfully will feed line drop the air inlet center line. Blast fur-nace at the same time serious damage on the furnace end campaign furnace shutdown technology are summarized, so that the feed line stop furnacetechnology has been further improved,
出处
《河南冶金》
2014年第1期40-41,53,56,共4页
Henan Metallurgy
关键词
高炉
停炉
空料线
blast furnace
blowing-down