超高层连体结构弹塑性时程分析 被引量:2

Elastic-plastic Analysis of the Super High-rise Connected Structure
下载PDF
导出
摘要 本文以一超高层连体结构实际工程为例,采用Midas Building有限元软件对该结构进行详细弹塑性时程计算分析,采用了单体和连体2种计算模型。由计算结果知,该结构塔楼单体模型最大弹塑性层间位移角为1/102,连体为1/135,均满足规范要求的最低标准1/100。并对该工程结构构件进行抗震性能评价,2种计算模型剪力墙、框架柱、连接体构件均未屈服,连梁与框架梁出现塑性铰,但均未达到CP状态。从2种计算模型损伤结果来看,该连体结构应采用2种计算模型的包络进行设计。 In this paper, an actual engineering of super high-rise connected structure as an example, by using the finite element software of Midas Building, the plastic time-history of the super high-rise connected structure is analyzed and calculated in details, by using two calculation models of monomer and connector. Based on the calculation results, the plastic interlayer maximum displacement angle of monomer model is 1/102, and the connector model is 1/135, both meet the specification required minimum standard 1/100. And making seismic performance evaluation of the structural elements for the project, the shear wall, frame column and connecting body member of the two calculation did not yield, the related beam and frame beam appear plastic hinge, but both did not reach the status of CP. The damage results from the two calculation models show that the design of the connected structure should be designed envelop by the two calculation models.
出处 《工程抗震与加固改造》 北大核心 2014年第1期10-17,共8页 Earthquake Resistant Engineering and Retrofitting
关键词 超高层连体结构 弹塑性时程分析 抗震性能评价 super high-rise connected structure plastic time-history analysis seismic performance evaluation
  • 相关文献

参考文献7

  • 1JGJ3-2010,高层建筑混凝土结构技术规程[S].
  • 2JGJ 3-2010,Technical Specification for Concrete Structures of Tall Building[S].
  • 3GB50011-2010,建筑抗震设计规范[S].
  • 4GB 50011-2010,Code for Seismic Design of Building[S].
  • 5结构大师非线性分析技术手册[M].北京:北京迈达斯技术有限公司,2009.
  • 6The Technical Manual of Structure Master Nonlinear Analysis[S].Beijing:MIDAS Information Technology Co.,Ltd,2009.
  • 7American Society of Civil Engineers.Seismic Rehabilitation of Existing Buildings[S].Reston:ASCE/SEI41,2007.

共引文献2136

同被引文献17

  • 1汤少强.高层连体结构变形调控施工技术研究[J].硅谷,2008,1(3):33-33. 被引量:3
  • 2朱鸣,王春磊,张徐.弱连体结构整体模型与单体模型时程分析对比研究[J].建筑结构,2011,41(S1):195-199. 被引量:4
  • 3中华人民共和国住房和城乡建设部.JGJ3-2010高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2010.
  • 4中华人民共和国住房和城乡建设部.GB500011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 5周巧伶.罕遇地震作用下柔性连接连体结构的弹塑性地震响应分析[D].南昌:南昌大学,2012.
  • 6Izuru T , Masaaki T. Fundamental properties on earthquake input en- ergy to two structures connected by passive dampers. Journal of Struc- tural and Construction Engineering (Transactions of AIJ) , 2007 ;616 (6) :81-75.
  • 7Masaaki T, Izuru T. Seismic retrofitting of low-rise building via out- frame systems connected by viscous dampers. Journal of Structural and Construction Engineering ( Transactions of AIJ), 2007 ;627 ( 2 ) : 55-62.
  • 8Tsukaa I, Masaaki T, Shinta Y, et al. Inverse problem approach to stiffness-damping design of outer-frame type seismic retrofitting. Jour- nal of Structural and Construction Engineering (Transactions of AIJ), 2008 ;73 (627) :725-732.
  • 9Ogawak T. Combined non-linear analysis for plane frame ( "clap" ). Architectural Institute of Japan Proc of 17th Symposium on ComputerTechnology on Information Systems and Applications, Tokyo: Showa Intelligence Press, 1994 : 79-84.
  • 10蔡晓鸿,孙书森,刘凤鸣,林顺旺,马景春,徐自国.当代MOMA工程高层多塔楼、高位悬挑及连体结构设计与施工关键技术研究[J].工程质量,2009,27(11):86-92. 被引量:3