摘要
[目的]建立离子色谱法测定再造烟叶中的钠、氨、钾、镁、钙的含量。[方法]采用0.05 mol/L盐酸溶液作为提取溶液,在超声波辅助条件下提取30 min,离子色谱法准确快速地同时检测出再造烟叶中的钠、氨、钾、镁、钙5种阳离子的含量。[结果]该方法对于钠、氨、钾、镁、钙5种阳离子的检出限和定量限分别为0.01和0.05μg/ml,0.06和0.019μg/ml,0.03和0.012μg/ml,0.04和0.013μg/ml,0.15和0.048μg/ml,5种阳离子3个浓度梯度的加标回收率范围均在91.7%~109.9%。用建立的方法对市场上常用的几种再造烟叶进行了测定显示,低含量的氨离子和钠离子含量的偏差分别为51.17%和51.96%,而高含量的镁、钾和钙离子含量偏差均在20%以内。[结论]该研究建立的方法具有操作简便、准确度高、重复性好、适用性强等优点,适用于大批量样品分析。
[ Objective ] To determine the content of sodium,potassium,ammonia,magnesium,calcium in reconstituted tobacco sheet by Ion-chro- matography. [ Method] Using 0.05 mol/L hydrochloric acid solution,extracting for 30 rain with ultrasonic assistant method, Ion-chromatography was adopted to accurately and rapidly determine content of sodium,potassium, ammonia, magnesium,calcium. [ Result ] The detection limit and quantification limit of the method on sodium ,ammonia ,potassium,magnesium,calcium are 0.01 and 0.05 μg/m1,0.06 and 0. 019 μg/m1,0.03 and 0. 012 μg/m1,0.04 and 0. 013 μg,/ml,0.15 and 0. 048 μg/ml, respectively. The range of recovery rate of standard addition is 91.7% - 109.9%. The deviation between low content ammonium and sodium is 51.17% and 51.96% ,deviation of high content magnesium ,potassium and calcium is within 20%. [ Conclusion] The established method has advantages of simple operation, high accuracy, good repeatability, strong adapt- ability,which is appropriate for multitudinous samples analysis.
出处
《安徽农业科学》
CAS
2014年第2期575-576,635,共3页
Journal of Anhui Agricultural Sciences
关键词
离子色谱法
再造烟叶
钠
钾
氨
镁
钙
Ion-chromatography
Reconstituted tobacco sheet
Sodium
Potassium
Ammonia
Magnesium
Calcium