期刊文献+

基于火灾场景的大型浮顶储罐区全过程风险防范体系研究 被引量:11

Study on whole-process risk precaution framework for large floating roof tanks based on fire scenarios
下载PDF
导出
摘要 针对大型浮顶罐区火灾事故风险特征,通过对火灾场景辨识及其火灾风险影响因素分析,结合预防初期火灾场景风险要素和消防系统有效性,提出了罐区火灾事故现实风险的评估框架及确定方法。在此基础上,构建了基于火灾场景的全过程风险防范体系,包括库区评估规划、罐体本质安全化设计、库区火灾预防、罐区火灾扑救、园区火灾事故管理等5个方面,并给出相应的对策措施。大型浮顶罐区全过程火灾风险防范是一个持续改进的结构化过程风险管理体系,有助于实现罐区火灾风险的过程安全管理,进而提高仓储型园区的整体消防安全保障能力和风险防控水平。 In accordance with the fire risk characteristics of large floating roof tank farm and oil depot,the fire scenarios and risk factors were analyzed and identified,and the assessment framework and methods of real fire risk for floating tank farm were proposed,including the preventive risk factors of initial fire scenario and availability of fire protection system. Moreover,a whole process risk precaution framework for large floating roof based on the fire scenarios was established with evaluation and plan of rank depot area,inherent safety design of tank,fire prevention and protection of oil storage area,fire accidents management of park area and so on,and the related fire precautionary countermeasures were described. This whole process fire risk precaution framework is a continually improved and structured risk management system,and helps to carry out process safety management of fire risk. Furthermore,it has some important value and roles to enhance the whole fire support ability and risk prevention and control level for storage park area.
作者 任常兴
出处 《中国安全生产科学技术》 CAS CSCD 2014年第1期68-74,共7页 Journal of Safety Science and Technology
基金 "十二五"国家科技支撑计划课题(2011BAK03B08)
关键词 火灾场景 大型浮顶罐 全过程 风险防范体系 fire scenario large floating roof tank whole process risk precaution framework
  • 相关文献

参考文献9

  • 1张兴权,马恒,智会强.“7·16”火灾的思考——探讨《石油库设计规范》存在的问题与修改[J].消防科学与技术,2010,29(9):783-785. 被引量:8
  • 2BRANDFORSK Project 513-021. Tank Fires Review of fire incidents 1951-2003 [ R]. SP Fire Technology, SP REPORT 2004 : 14.
  • 3Persson, B., LSnnermark, A., Persson, I-I., et al. FOAMSPEX - Large Scale Foam Application - Modelling of Foam Spread and Extinguishment, SP Swedish Nation- al Testing and Research Institute, SP Report 2001:13, Boris, Sweden, 2001.
  • 4API PUBLICATION 2021A (FIRST EDITION, JULY 1998), Interim Study-Prevention and Suppression of Fires in Large Aboveground Atmospheric Storage Tanks IS].
  • 5郎需庆,刘全桢,宫宏.大型浮顶储罐灭火系统的研究[J].消防科学与技术,2009,28(5):342-345. 被引量:39
  • 6Gabriele Landucci, Gianfilippo Gubinelli, Giacomo Anto- nioni, et al. The assessment of the damage probability of storage tanks in domino events triggered by fire [ J ]. Ac- cident Analysis and Prevention, 2009, (41) :1206-1215.
  • 7CPR 18 E. Guidelines for quantitative risk assessment, purple book [ M ]. Den Haag, Committee for the Preven- tion of Disasters, 1999.
  • 8LASTF|RE Project. Risk Reduction Options [ R]. 1997.
  • 9API RECOMMENDED PRACTICE 2021 (FOURTH E- DITION, MAY 2001 ), Management of Atmospheric Storage Tank Fires [ S ].

二级参考文献12