期刊文献+

一种脉宽调制的高稳定连续可调直流电压源 被引量:1

A Consecutively Adjustable and High Stable DC Voltage Source with PWM Chopped Modulator
下载PDF
导出
摘要 介绍了一种以深埋齐纳电压基准元件LTZ1000A主电路为基础,结合脉宽调制技术实现的在0~10V范围内连续可调的高稳定直流电压源。选用精密电阻并采用适当的保温与隔离措施,实现了电压基准主电路输出高稳定7V电压,其短期稳定性达到1.7×10^-8。利用具有相同温度系数和阻值的精密电阻组成比例升压电阻网络,使输出10V电压的短期稳定性为2.4×10^-8。同时利用脉宽调制并经DC—DC转换电路及滤波电路得到0~10V的电压输出,短期稳定性可在10^-7量级左右。 A continuously adjustable high stable DC voltage reference based on subsurface Zener reference LTZ1000A is presented and PWM technique is adopted to output voltages between 0 - 10 V. With selecting high precise resistors and using appropriate measures to insulate and isolate, the short-time relative stability of 7 V output voltage provided by LTZ 1000 is 1.7× 10^-8. The voltage of 10 V is increased up by a network,composed by high precise resistors with the same temperature coefficient, and its short-time relative stability is 2.4 × 10^-8. The voltage of 0 - 10 V generated by PWM technique and suitable DC-DC conversion-filter circuit are measured and the short term relative stabilities are about 10^-7 .
出处 《计量学报》 CSCD 北大核心 2014年第2期169-172,共4页 Acta Metrologica Sinica
关键词 计量学 直流电压源 脉宽调制 连续可调 高稳定 Metrology DC voltage source PWM Continuously adjustable High stable
  • 相关文献

参考文献6

二级参考文献17

  • 1张钟华.量子计量基准发展的最新动向 基本物理常数与SI基本单位的重新定义[J].中国计量,2006(3):6-9. 被引量:6
  • 2李洪,顾大伟.提高恒流源稳定性的技术措施[J].电测与仪表,1990,27(6):21-22. 被引量:2
  • 3I. M. Mills, P. J. Mohr, T. J. Quinn, et al. Redefinition of the Kilogram: A Decision Whose Time Has Come[J]. Metrologia, 2005, 42 (2) : 71 -80.
  • 4STEINER R L, WILLIAMS E R. Uncertainty Improvements of the NIST Electronic Kilogram[ J]. IEEE Trans. Instrum. Meas. 2007,56 (2) : 592-596.
  • 5Z. Zhang, Q. He, Z. Li. An Approach for Improving the Watt Balance [ A]. Filippo LEVI and Macro PISANI, CPEM 2006 [ C ], Tori no, Italy: 2006:126 - 127.
  • 6于百江.高稳定度稳定电源的分析与设计.电测与仪表,1981,:15-23.
  • 7于百江 龚树仁.高稳定度晶体管稳流源.电测与仪表,1980,:10-16.
  • 8Steimer P K,Steinke J K,Grüning H E. A reliable,interface-friendly medium voltage drive based on the robust IGCT and DTC technologies [A]. Proc of IEEE IAS Annual Meeting [C]. Phoenix Arizona,1999. 1505-1512.
  • 9Jouanne A,Enjeti P N. Design considerations for an inverter output filter to mitigate the effects of long motor leads in ASD application [J]. IEEE Trans on Ind Appl,1997,33(5): 1138-1145.
  • 10Chen S,Lipo T A. Bearing currents and shaft voltages of an induction motor under hard- and soft-Switching inverter excitation [J]. IEEE Trans on Ind Appl,1998,34(5): 1042-1048.

共引文献79

同被引文献16

  • 1来清民,马涛.基于LTC2400的分布式高精度数据采集系统的设计[J].微计算机信息,2006,22(05S):127-129. 被引量:3
  • 2吕正. 低温辐射计在我国的发展现状[C]. 中国光学学会学术大会,2004.
  • 3MARTIN J E,陈遐举.用于辐射绝对测量的超低温辐射计[J]. 国外计量,1986(3):60-63.
  • 4林延东,吕亮,李奇.低温辐射计的温度测量的研究[C] 第十一届全国光学测试学术讨论会论文 2006.
  • 5LEVINE P D,JAEGER K B.PrecIdion ac Measurement of Temperature Below 90K CPEM[P],1998.
  • 6àNGEL C, óSCAR C. High Resolution Temperature Measurement [J]IEEE,2004,7803-8692.
  • 7VOLKER H. High Accuracy Measuring Method of Absolute Tempreratures Using Thermistors.2005.
  • 8FANG Y X,ZHOU L K.A High-precision temperaturemeasurement system based on noise cancellation [J]. IEEE,2013.
  • 9陈斌,陈素颖,程健.高精度直流传感器DCCT标准测试系统- [J]. 中国物理C,2008(S1):43-45.
  • 10程兆兰,张龙生.2-100K标准锗电阻温度计的电阻—温度特性的测试[J]. 计量技术,1984(1):25-29.