摘要 炼油厂水冷器中的汽油、柴油和溶剂等介质的渗漏,直接影响循环水场的水质质量。文中分析了不同介质渗漏对水场水质及外观现象的影响规律,并通过实测数据和表观现象,准确地判断渗漏介质的类别,尽快找出生产装置漏点,减少了水场的运营成本。 The leakage of gasoline,diesel and solvent from the water cooler of the oil refinery directly affects water quality of thecirculating water unit. This paper analyzed the influence rule of leakage of different mediums on water quality and its apparentphenomenon of water unit,The categories of leaked mediums is accurately judged through the measured data and apparentphenomenon,the leaking points of production units can be found out as soon as possible,and thus the operating costs of the waterunit is reduced.