摘要
非接触供电技术由于其灵活、安全、可靠等优点有着很广阔的应用前景。通过应用不动点分析法对LCL谐振型软开关CPS进行电路建模分析,给出了软开关工作点计算方法步骤及结果,并且给予的验证。
Because contactless power supply technology is flexible,secure,and reliable then it has a very broad application prospects.In this paper,circuit modeling and analysis the LCL resonant soft-switching CPS with the fixed point analysis method,then comes out with the soft-switching operating point calculation procedures and results,and give validation.
出处
《工业控制计算机》
2014年第1期116-118,共3页
Industrial Control Computer
关键词
非接触供电系统
软开关工作点
不动点
contactless power system,soft-switching operating point calculation,LCL,fixed point analysis method