摘要 天然气的应用在我国尚处于起步阶段,输气管网的建设将成为今后几十年能源升级换代的主要投资方向。提高管网输配气的压力将提升传输效率和节省建设投资;气体流量计的使用压力也将随之升高,高压标定装置的需求将逐步增多。常压的流量溯源体系已经比较成熟,从如何选取高压气体流量原级装置的视角探讨高压进气式pVTt法流量标准装置的原理及设计,并提出简化计算实例。希望对今后我国原级气体流量标准装置的建设提供参考。 In our country, the application of natural gas is only at the initial stage, so in the coming decades, the construction of gas transmission pipeline network will become the main investment direction for energy upgrades. Raising the pressure of the gas transmission and distribution pipeline network is the good way to improve the transmission efficiency and save the construction investment, while the operation pressure of the gas flow meters will be definitely higher, and the demands for high pressure calibration facility will gradually increase. The traceability for flow calibration under normal pressure is mature, the principle and design of high pressure intake pVTt method flow standard facility are investigated from the viewpoint of how to select high pressure gas flow primary facility, and the simplified calculation example is proposed. Hopefully, this will provide reference for the construction of primary gas flow standard facilities in our country.
作者 陈弘
出处 《自动化仪表》 CAS 北大核心 2014年第2期58-60,65,共4页 Process Automation Instrumentation
关键词 高压进气式 原级基准 pVTt法 标准容器 换向器 High pressure intake Primary standard pVTt method Standard vessel Diverter
  • 相关文献

参考文献9

  • 1国家质量监督检验检疫总局.JJG619.2005PVTt法气体流量标准装置检定规程[S].2005.
  • 2李传经,王继忠.流量计量的趋同性研究和试验方法[C]//第八届工业仪表与自动化学术会议.2007.
  • 3Johnson A N. Natural gas flow calibration services[ M]. NIST Special Publications 1081,2007.
  • 4Bowles E B, Grimiey T A. Flow calibration laboratory performance- what should your expectations be[ J]. Flow Control Magazine,2001.
  • 5TUV NEL. Gas flow test facilities [ EB/OL ]. [ 2013 - 12 - 12]. TUV NEL,Technical Document.
  • 6Michan B, Kramer R, PTB. Comparisons by PTB, NIST and LNE- LADG in air and natural gas with critical venturi nozzles agree within 0.05% [ C]//6^th ISFFM,2006.
  • 7JJG620—2008.临界流文丘里喷嘴检定规程[S].2008.
  • 8李传经 陈云麒 王继忠.天然气流量仪表在高压下的标定.计量技术,2008,(1):3-7.
  • 9Johnson A N ,Wright J D. Gas flowmeter calibrations with the 26m^3 pVTt standard[M]. NIST Special Publications 1046,2004.

共引文献1

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部