期刊文献+

人胸部电阻抗成像和铜测量电极系统初步研究 被引量:3

Primary research on copper EIT electrode and thoracic EIT based on the copper electrode array
下载PDF
导出
摘要 目的 由铜构建的 32测量电极 ,安置于人体胸部 ,观察肺呼吸时胸部电阻率的变化情况 .方法 用铜片制成 32电极 ,固定于成年健康男性胸部进行测量 ,用等位线反投影算法对数据进行图像重构计算 .结果 获得了胸部电阻率在肺呼吸时的变化图像 ,图像显示肺在呼吸前后 ,肺部区域电阻率变化最为明显 .结论 用铜实现的电极系统可以进行电阻抗断层成像 (EIT) ,而且 EIT功能成像的特点也得到了进一步证实 . AIM To construct a thoracic electrical impedance tomography (EIT) measurement system which is based on 32-electrode made of Copper, and to explore the correlation between thoracic resistivity change and volume of air breathed. METHODS In vivo measurement of the impedance of healthy adult thorax was made under dynamic conditions. The dynamic images about the resistivity of thorax changes were reconstructed by means of backprojecting algorithm. RESULTS Several images of thoracic resistivity variations during lung ventilation were obtained, which showed the regions of high corresponding to the two lungs. CONCLUSION Suitability of this electrode system has been demonstrated and the ability of function imaging of EIT has been corroborated as well.
出处 《第四军医大学学报》 北大核心 2001年第2期178-179,共2页 Journal of the Fourth Military Medical University
基金 国家科委"九.五"攻关项目! (96 -92 0 -12 -0 4)
关键词 电阻抗成像 铜测量 电极 胸部电阻率 electric impedance electrode thorax lung tomography, X-ray computed
  • 相关文献

参考文献1

  • 1Qi B Y,医学仪器,1990年,53页

同被引文献11

  • 1任超世,池学东,崔云莉,王慧艳,林国京.电阻抗断层图像技术[J].中国医学物理学杂志,1997,14(2):122-125. 被引量:5
  • 2Jaroslaw Stelter and Antoni Nowakowski. Digital demodulator procedure for impedance mammography. 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Amsterdam 1996, 1942-1944
  • 3Webster JG. Electrical Impedance Tomography, 1990. Adam Hilger,Bristol and New York. 50-52
  • 4H Dehghai,D C Barber.,I Basarrab-Horwath.Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography Physiol.Meas,1999,20:87~102
  • 5Saacson D.,Isaascson E.L.Comment on Calderon's paper:On aincrea se boundary value problem.Math Comput,1989,52:553~559
  • 6Holder.Temple.Effectiveness of the Sheffield EIT system indisting uishing patients with pulmonary pathology from a series of normal subjects.In:Holder DS.Clinical and Physiological Applications of Electrical Impedance Tomography.London:UCL Press,1993
  • 7Watanabe R,Kotoura H,Morishita Y.CT analysis of the use of the electrical impedance technique to estimate local oedema in the extremities in patients with lymphatic obstruction.Med Biol EngCom put,1998,36:60~64
  • 8尤富生,董秀珍,秦明新,史学涛,汤孟兴,刘锐岗.一个32电极电阻抗断层成像硬件系统[J].医学争鸣,1998(S1):7-9. 被引量:6
  • 9付峰,臧益民,董秀珍,王跃民.部分离体动物组织复阻抗频率特性(100HZ~10MHz)测量系统及初步测量结果[J].第四军医大学学报,1999,20(3):220-222. 被引量:24
  • 10刘锐岗,董秀珍,秦明新,尤富生,史学涛,FU Feng,付峰,汤孟兴.基于物理模型的静态电阻抗断层成像初步结果[J].第四军医大学学报,2001,22(4):297-300. 被引量:4

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部