三种仪器测量LASEK术后中央角膜厚度的比较 被引量:2

Comparison of central corneal thickness measurements after LASEK by three instruments
下载PDF
导出
摘要 目的:比较光学相干断层扫描(optical coherence tomography,OCT)、角膜内皮计与超声测厚仪测量准分子激光上皮下角膜磨镶术(laser subepithelial keratomileusis,LASEK)术后患者中央角膜厚度(CCT)的差异性和相关性。方法:选取LASEK术后6mo复诊的近视患者49例96眼,对每位患者分别用OCT、角膜内皮计、超声测厚仪三种仪器测量其CCT,数据统计分析采用配对t检验和Pearson相关性分析。结果:OCT、角膜内皮计、超声测厚仪测量CCT的平均值为分别为475.15±33.67,447.80±34.11,465.18±34.23μm。手术预留CCT平均值为431.22±35.32μm。三种仪器所测量结果之间两两比较差异均有统计学意义(P<0.05)。线性相关显示超声测厚仪与OCT、角膜内皮计两种仪器之间存在正相关(r=0.949,0.983,P<0.01)。LASEK术后实际CCT较手术预留角膜厚度要厚。结论:三种仪器的中央角膜厚度测量值不可互换。 AIM: To compare the differences and the relationships of central corneal thickness ( CCT) measurements among optical coherence tomography ( OCT ) , Tomey pachymetry and ultrasound pachymetry after laser assisted subepithelial keratomileusis ( LASEK) . METHODS:Forty-nine patients ( 96 eyes ) with myopia after 6mo of LASEK were assigned to measure the CCT by OCT, Tomey pachymetry and ultrasound pachymetry. Paired t-test and Pearson correlation analysis was used for statistical analysis. RESULTS: The mean CCT measured by OCT, Tomey pachymetry and ultrasound pachymetry was ( 475.15 ± 33.67μm), (447.80 ±34.11μm), (465.18 ±34.23μm), respectively.Surgery reserved mean CCT was ( 431.22 ± 35.32 )μm.There were statistically differences between two comparative measured results (P&lt;0.05).Ultrasound pachymetry had a positive correlation with OCT and Tomey pachymetry ( P &lt;0.01 ), and the correlation coefficient was 0.949 and 0.983, respectively.The actual CCT of 6mo post-operation was thicker than surgery reserved CCT. CONCLUSION: The CCT measurements of three instruments were not interchangeable.
出处 《国际眼科杂志》 CAS 2014年第3期477-479,共3页 International Eye Science
关键词 光学相干断层扫描 角膜内皮计 超声角膜测厚仪 中央角膜厚度 optical coherence tomography Tomey pachymetry ultrasound pachymetry central corneal thickness
  • 相关文献

参考文献6

  • 1莫婷,沈政伟,姜黎,尹禾,李丽,吴金桃.四种仪器测量近视眼角膜中央厚度的比较[J].临床眼科杂志,2012,20(3):211-214. 被引量:5
  • 2Cheng AC, Ho T, Lau S, et al. Measurement of LASIK flap thickness with anterior segment optical coherence tomography. J Refract Surg 2008 ; 24(9) :879-884 3.
  • 3Williams R,Fink BA, King-Smith PE ,et al. Central corneal thickness measurements: using an ultrasonic instrument and 4 optical instruments. Cornea 2011 ;30( 11 ) :1238-1243 4.
  • 4Li Y,Shekhar R, Huang D. Corneal pachymetry mapping with high- speed optical coherence tomography. Ophtham!ology 2006 ; 113 (5) :792-799 5.
  • 5Modis L Jr, Szalai E, Nemeth G, et al . Evaluation of a recently developed non- contact specular microscope in comparison with conventional pachymetry devices. Eur J Ophthalmol 2010;20(5) :831-838 6.
  • 6Wong AC, Wong CC, Yuen NC, et al. Correlational study of central corneal thickness measurements on Hong Kong China using optical coherence tomography, Orbscan and ultrasound pachymetry. Eye 2002; 16:715-721.

二级参考文献13

  • 1张波涌,钟华,袁玲,牛志强,李含玉,袁援生.角膜内皮细胞计和超声角膜测厚仪测量角膜中央厚度的比较[J].云南医药,2004,25(4):283-285. 被引量:1
  • 2Wong AC,Wong CC,Yue NC,et al. Conelational study of central corneal thickness measurements on Hong Kong China using optical coherence tomography, and ultrasound pschymetry. Eye, 2002,16:715-721.
  • 3齐颂扬.医学仪器(下).北京:高等教育出版社,1991:250.
  • 4Wheele NC. Reliability codllcieats d three ccaneal pachymeters. Am J Ophthalmal, 1992 ,113 :645-650.
  • 5BronA. The cornea thickness mareamt reliable and usdul. J Fr Ophtalmol, 1999,22 : 160-165.
  • 6LacknerB. Repeatability and zeproducibifity of the central corneal thickness measurement with Pentacam, mid ultrasound. Opthom Vis Sci,2005,82:892-899.
  • 7Hashemi H. Central corneal thickness measurement with Penta- cam,ObscanII and ultrasound devices before and edger laser frative surgery for myopi. C,act Refract Surg, 2007,33 : 1701- 1707.
  • 8Airiani S, Trokel SL, Lee SM, et al. Evaluating central corneal thickness measurements with noncontact optical low-coherelce xe- flectometry and contact ultrasound pachymetry. Am J Ophthalmol, 2006,142:164-165.
  • 9Spadea L,Giammarla D,Di C,eova L,et al. Comparison of optical low coherence rdlectometry and ultrasound pachymetry in the d central cneal thickness before and after photole- fractive kemtectomy. J Refract Surg,2007 ,23 :661-666.
  • 10Tam ES, Rootman DS. Comparison of centnd corneal thickness measurements by specular microscopy, ultrasmnd pachymetry, and ultrasound biomicroscopy. J Catct Refract Surg,2003,6: 1179-1184.

共引文献4

同被引文献45

  • 1王卫群,张幼梅,史苏爱,田庆丰.中央角膜厚度的测量及与眼压的关系[J].眼科研究,2004,22(5):529-529. 被引量:7
  • 2周佳奇,周行涛.角膜厚度测量新进展[J].国际眼科纵览,2007,31(4):239-242. 被引量:4
  • 3Gros-Otero J, Arruabarrena-Sdnchez C, Teus M. Central corneal thickness in a healthy Spanish population[J]. Arch Soc Esp Oftal- mol,2011,86(3) :73.
  • 4Linke SJ ,Ceyrowski T,Steinherg J, et al. central versus tnmnwL pachymetry of the cornea and thinnest point vector length:impact of ocular side, refractive state, age, and sex[J]. Cornea, 2013,32 (5) :e127.
  • 5Hoffmarm EM, Lamparter J, Mirshah[ A, et al. Distr~btttion of central corneal thickness and its association with ocular parame- ters in a large central European cohort: the Gutenberg health study[J]. PLoS One,2013,8(8) :e66158.
  • 6Galgauskas S, Norvydait D, Krasauskait D, et al. Age-relatedchanges in corneal thickness and endothelial characteristics[J]. Clin Interv Aging, 2013,8 :1445.
  • 7Filipecka I, Nowak A, Lewicka K, et al. Evaluate central corneal thickness in patients from Podbeskidzie area in adult patients[J]. Klin Oczna,2013,115(2) :121.
  • 8Saeedi O,Pillar A,Jefferys J, et al. Change in choroidal thickness and axial length with change in intraocular pressure after trabecu- lectomy[J]. Br J Ophthalmol, 2014,98(7) : 976.
  • 9Nebbioso M, Fazio S, Di Blasio D, et al. Hypobaric hypoxia: effects on intraocular pressure and corneal thickness[J]. Scien- tific World Journal ,2014,2014 : 585218.
  • 10赵家良.正常人与原发性闭角型青光眼的角膜厚度[J].眼科研究,1986,2(2):91.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部