期刊文献+

铁线处理COD cr测定废液 被引量:1

Iron lines treating waste water of CODcr measurement
下载PDF
导出
摘要 重铬酸钾法测定COD废液中含有较高浓度Hg2+、Ag+、Cr(VI)、Cr3+和H2SO4,不处理排放严重污染环境。我们采用加铁线于废液中,铁置换Hg2+、Ag+生成汞银合金析出,Cr(VI)还原为Cr3+,然后加碱中和,过滤,除去Cr(OH)3沉淀,最后各离子均达到污染物排放标准要求。本方法比先前工作者处理方法简便彻底。 The waste water of chemical oxygen demand(COD)by potassium dichromate method has high concentration of Hg2+,Ag+,Cr(VI),Cr3+and H2SO4. Discarding the waste water without treatment will contaminate environment seriously. We put iron lines in the waste water;iron replaces Hg2+,Ag+then mercury and silver alloy is deposited;Cr(VI)is reduced into Cr3+ then alkali is added to neutralized,filtering to remove the Cr(OH)3 precipitation. Finally all cations reach the standard level of pollutant discharging. It’s believed that this method is easier and more complete than others.
出处 《福建分析测试》 CAS 2014年第2期60-62,共3页 Fujian Analysis & Testing
关键词 CODcr废液 铁线置换还原 碱中和 达标排放 waste water of CODcr iron lines replacement and reduction alkali neutralization discharging to reach the standard
  • 相关文献

参考文献7

二级参考文献12

  • 1姚淑霞,霸书红.废液中COD_(Cr)的治理与利用[J].中国环境管理干部学院学报,2004,14(2):27-29. 被引量:2
  • 2王俊荣.COD_(Cr)测定废液中银的回收与利用[J].工业用水与废水,2005,36(3):16-18. 被引量:5
  • 3张泉泓,徐洪波.废液中汞的回收和利用[J].辽宁化工,1997,26(2):90-90. 被引量:2
  • 4国家环保总局《水和废水监测分析方法》编委会.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002..
  • 5国家环保局编.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.417-419.
  • 6杭州大学化学系分析化学教研室编.分析化学手册[M].第二分册.北京:北京化学工业出版社,1982.107.
  • 7奚旦高主编.环境监测[M].高等教育出版社,1995.13.
  • 8林树昌主编.定性分析学[M].北京:北京师范大学出版社,1990.54.
  • 9水和废水监测分析方法[M].第4版.北京:环境科学出版社.2002.210-213.
  • 10环境影响评价技术方法[M].北京:中国环境科学出版社,2007.220-232.

共引文献58

同被引文献22

引证文献1