摘要 Background Currently,adhesive technique is popular in vascular repair but not widely used for defective vessels.This study aimed to determine the feasibility and effectiveness of repairing defective vessels with 2-octyl-cyanoacrylate and a homemade prosthetic component.Methods Homemade prosthetic component consisting of expanded polytetrofluoroethylene (ePTFE),terylene film,and homemade soluble hollow stent mixed with adhesive can replace autologous graft and suture in repairing defective vessels,can fix vessels better using the stent without occlusive bleeding.Forty male mongrel dogs were used,20 for biomechanical tests and 20 for animal experiments.In the biomechanical test,dogs were randomly divided into two groups (n=10 each),one group repaired on the two sides of the carotid arteries with 2-octyl-cyanoacrylate and homemade component and another group repaired with suture and ePTFE.Of the 40 specimens,10 were used for adhesive and 10 for suture specimens for tension strength test,whereas the remaining specimens were used for bursting pressure test.In animal experiments,dogs were also divided into adhesive and suture groups (n=10),only of the left carotid artery.Recording the operational time,bleeding or not.Vessels were tested using color Doppler ultrasound,the inner diameter was measured,and the degree of stenosis at 8 weeks was evaluated digital subtraction angiography (DSA) were also performed.Specimens were then analyzed histologically.Results In the adhesive and suture groups,the specimens could afford atension strength of (23.80±1.51) N versus (24.60±1.08) N (P >0.05),the bursting pressure was (52.03±.2.43) kPa versus (50.04±3.51) kPa (P >0.05),and the mean time of anastomosis was (15.20±0.55) minutes versus (25.97±0.58) minutes (P <0.05).One dog in the adhesive group was bleeding from the suture.One dog from each group presented with thrombosis at 1 week.After measuring using ultrasound,the stenosis degree of all dogs were no more than 30% except the two thromboses.DSA and histological observation showed no obvious difference between the two groups.Conclusion Defective vascular anastomosis with 2-octyl-cyanoacrylate and our homemade prosthetic component is feasible,effective,timesaving,and easy to master. Background Currently,adhesive technique is popular in vascular repair but not widely used for defective vessels.This study aimed to determine the feasibility and effectiveness of repairing defective vessels with 2-octyl-cyanoacrylate and a homemade prosthetic component.Methods Homemade prosthetic component consisting of expanded polytetrofluoroethylene (ePTFE),terylene film,and homemade soluble hollow stent mixed with adhesive can replace autologous graft and suture in repairing defective vessels,can fix vessels better using the stent without occlusive bleeding.Forty male mongrel dogs were used,20 for biomechanical tests and 20 for animal experiments.In the biomechanical test,dogs were randomly divided into two groups (n=10 each),one group repaired on the two sides of the carotid arteries with 2-octyl-cyanoacrylate and homemade component and another group repaired with suture and ePTFE.Of the 40 specimens,10 were used for adhesive and 10 for suture specimens for tension strength test,whereas the remaining specimens were used for bursting pressure test.In animal experiments,dogs were also divided into adhesive and suture groups (n=10),only of the left carotid artery.Recording the operational time,bleeding or not.Vessels were tested using color Doppler ultrasound,the inner diameter was measured,and the degree of stenosis at 8 weeks was evaluated digital subtraction angiography (DSA) were also performed.Specimens were then analyzed histologically.Results In the adhesive and suture groups,the specimens could afford atension strength of (23.80±1.51) N versus (24.60±1.08) N (P >0.05),the bursting pressure was (52.03±.2.43) kPa versus (50.04±3.51) kPa (P >0.05),and the mean time of anastomosis was (15.20±0.55) minutes versus (25.97±0.58) minutes (P <0.05).One dog in the adhesive group was bleeding from the suture.One dog from each group presented with thrombosis at 1 week.After measuring using ultrasound,the stenosis degree of all dogs were no more than 30% except the two thromboses.DSA and histological observation showed no obvious difference between the two groups.Conclusion Defective vascular anastomosis with 2-octyl-cyanoacrylate and our homemade prosthetic component is feasible,effective,timesaving,and easy to master.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第5期882-886,共5页 中华医学杂志(英文版)
关键词 arteries injury CYANOACRYLATE prosthetic component suture techniques arteries injury cyanoacrylate prosthetic component suture techniques
  • 相关文献

参考文献20

  • 1Cihan HB,Gulcan O,Hazar A,Turkoz R. Peripheral vascular injuries. Ulus Travma Derg 2001; 7:113-116.
  • 2Kirsch WM,Zhu YH,Hardesty RA,Chapolini R. A new method for microvascular anastomosis:report of experimental and clinical research. Am Surg 1992; 58:722-727.
  • 3Kamiji T,Maeda M,Matsumoto K,Nishioka K. Microvascular anastomosis using polyethylene glycol 4000 and fibrin glue. Br J Plast Surg 1989; 42:54-58.
  • 4Shah AK,Clibbon JJ. Histoacryl(R) to secure the microvascular venous anastomosis using the coupling device. Microsurgery 2011; 31:666-667.
  • 5Ersoy OF,Kayaoglu HA,Celik A,Ozkan N,Lortlar N,Omeroglu S. Comparison of cyanoacrylate-assisted arteriotomy closure with conventional closure technique. Ulus Travma Acil Cerrahi Derg 2009; 15:535-540.
  • 6Zhu Y,Wei W,Li Y. 2-Octylcyanoacrylate-assisted microvascular anastomosis in rat orthotopic small bowel transplantation. J Reconstr Microsurg 2011; 27:151-156.
  • 7Chen YX,Chen LE,Seaber AV,Urbaniak JR. Comparison of continuous and interrupted suture techniques in microvascular anastomosis. J Hand Surg Am 2001; 26:530-539.
  • 8Baguneid MS,Goldner S,Fulford PE,Hamilton G,Walker MG,Seifalian AM. A comparison of para-anastomotic compliance profiles after vascular anastomosis:nonpenetrating clips versus standard sutures. J Vasc Surg 2001; 33:812-820.
  • 9Fernandez P,Deguette A,Pothuaud L,Belleannee G,Coste P,Bordenave L. Quality control assessment of ePTFE precoating procedure for in vitro endothelial cell seeding. Biomaterials 2005; 26:5042-5047.
  • 10Timmons M J,Continuous sutures for microarterial end-to-side anastomoses. Plast Reconstr Surg 1984; 74:544-547.