摘要
研究了不同介质中钒钼黄法的分析特性和干扰因素 ,选定盐酸介质建立了快速分析钒浸出液中磷的直接光度法 .该方法用钼酸钠作显色剂 ,显色酸度 1.2 N,λ =430 nm,ε =1300,0~ 400μ g线性良好 ;检测下限 1.67μ g(3s),共存组分无干扰 ,50~ 350μ g加标回收率 97.6%~ 102.1% ,100μ g中重复 11次分析 ,RSD=1.52% , X=100.48μ g.
Compared with analytical characteristics and interfering factors for different media,hydrochloric acid was chosen as media in direct absorbance measurement to analyse phosphorus of Vanadium- leached solution. In this method,ammonium sodium was chosen as chromogenic agent ,under the conditions that:the coloration acidity is 1.2 N,λ =430 nm,ε =1 300.We concluded that when phosphorus content is between 0~ 400μ g,Beer's law is obeyed;when phosphorus content is lower limit 1.67μ g(3s),the coexistence components don't interfere with phosphorus ;when phosphorus content is 50~ 350μ g,the adding standard sample rate of recovery is 97.76%~ 102.1% ;when phosphorus content is 100μ g,eleven times analyses are made and given.RSD=1.52% and X=100.48μg.
出处
《沈阳工业大学学报》
EI
CAS
2001年第1期89-92,共4页
Journal of Shenyang University of Technology
关键词
盐酸介质
磷钒钼黄
钒浸出液
分光光度法
磷
快速测定
phosphorus- Vanadium yellow
Vanadium- leached Solution
rapid analysis method
spectrophotometer method
phosphorus