期刊文献+

凝汽器低压缸减温水系统改造方法比较 被引量:1

Comparison of Modification Methods of Water Spraying Cooling System of Condenser Low Pressure Cylinder
下载PDF
导出
摘要 针对凝汽式汽轮发电机解列后,凝结水泵对低压缸及其相关系统喷水冷却过程所需外购电量大的问题,提出采用凝汽器补水泵或新增水泵替代凝结水泵为低压缸提供冷却水。经对比、分析及计算,采用凝补水泵或新增水泵替代凝结水泵均可大幅降低电耗,减少外购电量,缩短检修工期,有效降低运行成本。 Aiming at the problem that a large amount of purchased electricity is needed by the condensate pump for the water spraying cooling process of the low pressure cylinder and its corresponding system after the step-out of the condensing type steam turbine generator, it is proposed that the condensate pump should be replaced by the condenser water compensation pump or a new water pump to supply the cooling water. After the comparison, analysis and calculation, it is found that the replacement of condensate pump by the condenser water compensation pump or a new water pump can greatly reduce the energy consumption, which can reduce the purchased electricity, shorten the maintenance time and thus reduce the operation cost.
作者 陈召攀
出处 《广西电力》 2014年第1期73-74,共2页 Guangxi Electric Power
关键词 凝结水泵 低压缸 凝补水泵 condensate pump, low pressure cylinder, condenser water compensation pump
  • 相关文献

参考文献1

  • 1万鹏.600MW超临界机组汽机运行操作规程及系统图[Z].贵港:华电集团广西贵港发电有限公司电厂,2009.

同被引文献4