摘要
目的观察微酸性电解水用于手消毒的效果。方法将某综合医院94名医务人员及陪护家属分为三组,分别以15℃、5℃微酸性电解水以及百能抗菌洗手液按标准六步洗手法洗手1min,采用微生物培养计数法评价洗手后的消毒效果。结果 15℃水温的微酸性电解水洗手后对手部细菌平均清除率达99.65%,优于百能抗菌洗手液和5℃的微酸性电解水(均P<0.05)。结论15℃水温的流动微酸性电解水洗手消毒效果肯定。
Objective To observe the efficacy of slightly acidic electrolyzed water(SlAEW) on hand disinfection. Methods A total of 94 participants including doctors, nurses and family members of patients were randomly divided into three groups. Each of 3 groups was asked to wash hands according to the standard six-step hand washing protocol for one minute with SIAEW at 15℃ ,SIAEW at 5℃ or Banen antibacterial hand cleaner respectively. Disinfection efficacy was measured by using microbiological culture. Results SIAEW at 15℃ for hand washing improved the bacteria clearance rate to 99.65 %, which showed a high disinfectant efficacy corn pared to Banen antibacterial hand cleaner or the SIAEW at 5℃ (P(0.05 for both). Conclusion The use of SIAEW at 15℃ is sug gested as an effective disinfection method for hand washing.
出处
《护理学杂志(综合版)》
CSCD
2014年第3期4-5,共2页
Journal of Nursing Science
基金
上海交通大学医学院横向计划项目(JYh1205)
关键词
手卫生
洗手
手消毒
水温
微酸性电解水
百能洗手液
微生物培养计数法
细菌清除率
hand hygiene
hand washing
hand disinfection
water temperature
slightly acidic electrolyzed water
Bancnantibacterial hand cleaner
microbiological culture technique
bacteria clearance rate