摘要 陶瓷-陶瓷负重界面具有超高的硬度、极佳的润滑效应、出色的耐磨性和组织相容性,不释放有毒的金属离子,目前已广泛用于全髋关节置换术(total hip arthroplasty,THA)。但陶瓷是易碎材料,碎裂后将给患者带来灾难性的后果。本文从陶瓷碎裂的发生率、原因、发生机制、早期诊断、预防及治疗方面进行综述,为陶瓷-陶瓷负重界面的临床应用提供参考。
出处 《实用医院临床杂志》 2014年第2期177-180,共4页 Practical Journal of Clinical Medicine
  • 相关文献

参考文献29

  • 1Armala 10.Salmon calcitonin(miacalcic ns 200 iu)in prevention ofbone loss after hip replacement[J].Scand J Surg,2012,101(4):249-254.
  • 2Shetty V,Shitole B,Shetty G,et al.Optimal bearing surfaces for totalhip replacement in the young patient:a meta-analysis[J].Int Or-thop,2011,35(9):1281-1287.
  • 3Boutin P.Total arthroplasty of the hip by fritted aluminum prosthe-sis.Expermental study and 1st clinical applications[J].Rev Chir Or-thop Reparatrice Appar Mot,1972,58(3):229-246.
  • 4Toni A,Terzi S,Sudanese A.et al.Fracture of the ceramic epiphysisin hip arthroplasty[J].Chir Organi Mov,1996,81(1):11-19.
  • 5Aldrian S,Nau T,Gillesberger F,et al.Medium-term analysis ofmodem ceramic-on-ceramic bearing in THA[J].Hip Int,2009,19(1):3640.
  • 6Koo KH,Ha YC,Jung WH,et al.Isolated Fracture of the CeramicHead After Third-Generation Alumina-on-Alumina Total Hip Arthro-plasty fj].J Bone Joint Surg Am,2008,90(2):329-336.
  • 7Choy WS,Kim KJ,Lee SK,et al.Ceramic-on-Ceramic Total Hip Ar-throplasty:Minimum of Six-Year Follow-up Study[J].Clin OrthopSurg;2013’5(3):174-179.
  • 8Kim YH,Choi Y,Kim JS.Cementless total hip arthroplasty with ce-ramic-on-ceramic bearing in patients younger than 45 years with fem-oral-head osteonecrosis[J].Int Orthop,2010,34(8);1123-1127.
  • 9Chevillotte C,Pibarot V,Carret JP,et al.Nine years follow-up of 100ceramic-on-ceramic total hip arthroplasty f J].Int Orthop,2011,35(II):1599-1604.
  • 10Gustavo M,Bruno L.Strength of Materials[M].New York:NovaScience Publishers,2009:133-156.

二级参考文献50

  • 1陈文.氧化铝陶瓷在髋关节置换领域中的应用[J].生物骨科材料与临床研究,2005,2(6):5-8. 被引量:4
  • 2高辉,寇伯龙,吕厚山.全髋置换治疗先天性髋臼发育不良临床疗效观察[J].中国矫形外科杂志,2006,14(23):1778-1780. 被引量:16
  • 3Hellman EJ, Capello WN, Feinberg JR.Omnifit cementless total hip arthroplasty: a 10-year average followup. Clin Orthop, 1999 , 364:164-174
  • 4Charnley J, Cupic Z, The line and ten year results of the low friction arthroplasty of the hip. Clin Orthop, 1973, 95:9-25
  • 5Inghem E, Fisher J. Biological reactions to weer debris in total joint replacement. Proc Inst Mech Eng[H]. 2000; 214( 1 ) :21-37
  • 6Mahoney OM, Dimon JH 3rd. Unsatisfactory results with a ceramic total hip prosthesis J Bone Joint Surg Am, 1990, 72(5):663-671
  • 7Hamadouche M, Boutin P, Daussange J,et al. Alumina-on-alumina total hip arthroplasty: a minimum 18. 5-year follow-up study. J Bone Joint Surg Am, 2002, 84(1) :69-77
  • 8Lusty PJ, Tai CC, Sew-Hoy RP, et al. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am, 2007; 89(12) :2676-2683
  • 9Richater HG. Application of proof-testing to ceramic hip joint heads, bioceramics in orthopaedics: new applications. Proceedings of the 3rd International Symposium on Ceramic Wear Couple. Stuttgart,Germany, 1998:7-12
  • 10Granchi D, Ciapetti G, Amato I, et al. The influence or alumina and ultra-high molecular weight polyethylene particles on osteoblast-osteoclast cooperation. Biomaterials,2004; 25(18):4037-4045

共引文献23

同被引文献52

  • 1刘庆,殷建华,周乙雄,张洪,李玉军.陶瓷对陶瓷人工髋关节置换手术技巧及相关研究[J].中国矫形外科杂志,2007,15(14):1062-1064. 被引量:10
  • 2Hemigou P, Zilber S, Filippini P, et al. Ceramic-ceramic bearing de- creases osteolysis:a 20-year study versus ceramic-polyethylene on the eontralateral hip[J]. Clin Orthop Relat Res ,2009,467(9) :2274 -2280.
  • 3Hamilton WG, MeAuley JP, Dennis DA, et al. THA with Delta ceramic on ceramic: results of a multieenter investigational device exemption trial I J ]. Clin Orthop Relat Res ,2010,468 (2) :358 - 366.
  • 4Lombardi AV Jr, Berend KR, Seng BE, et al. Delta ceramic-on-alu- mina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis [ J ]. Clin Orthop Relat Res, 2010, 468(2) : 367 -374.
  • 5Lusty PJ, Tai CC, Sew-Hoy RP, et al. Third-generation alumina-on- alumina ceramic bearings in cementless total hip arthroplasty [ J ]. J Bone Joint Surg Am, 2007, 89 ( 12 ) : 2676 - 2683.
  • 6Lewis PM, A1-Belooshi A, Olsen M, et al. Prospective randomized trial comparing alumina ceramie-on-eemmie with cemmie-on-eonven-tional polyethylene bearings in total hip arthroplasty [ J ]. J Arthro- plasty, 2010, 25(3) : 392 -397.
  • 7Sexton SA, Yeung E, Jackson MP, et al. The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip re- placements[ J ]. J Bone Joint Surg Br, 2011, 93 (4) : 439 -442.
  • 8Stanat S JC, Capozzi JD. Squeaking in third-and fourth-generation ceramic-on-ceramic total hip arthroplasty: meta-analysis and system- atic review[J]. J Arthroplasty, 2012, 27(3) : 445 -453.
  • 9Choy WS, Kim KJ, Lee SK, et al. Ceramic-on-ceramic total hip m-- throplasty: minimum of six-year follow-up study [ J ]. Clin Orthop Surg, 2013,5(3) :174 - 179.
  • 10Kuo FC, Liu HC, Chen WS, et al. Ceramic-on-ceramic total hip ar- throplasty: incidence and risk factors of bearing surface-related noi- ses in 125 patients[ J]. Orthopedics ,2012,35 ( 11 ) : e1581 - e1585.

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部