摘要 小儿呼吸机撤机过早容易导致撤机失败,延长机械通气时间,会增加呼吸机相关并发症的风险和患者的经济负担。目前在儿科领域仍无统一客观的撤机指标,探索合理可行的呼吸机撤机指标对提高撤机成功率有重要意义。该文详述了目前sDJL呼吸机撤机条件及撤机指标的研究进展,比较各指标对小儿呼吸机撤机的预测性及准确性,并展望了更高预测准确度的撤机指标或撤机组合方案用于临床的可能性。 Early weaning from mechanical ventilation in children will lead to an extubation failure, however, prolonging mechanical ventilation will increase the risk of ventilator associated complication and the economical burden of disease. Nowadays there is no unified and objective ventilator weaning indexes in pedi- attics, so it is significant to searching for appropriate and feasible ventilator weaning indexes. This article de- tailed the current progress on the condition and predictors of ventilator weaning in children, and comparing the predictability and accuracy of ventilator weaning indexes in children, also looking forward to the possibility of higher accuracy or scheme in ventilator weaning that used for clinical purposes.
出处 《中国小儿急救医学》 CAS 2014年第3期174-176,共3页 Chinese Pediatric Emergency Medicine
关键词 机械通气 呼吸机撤机指标 儿童 Mechanical ventilation Ventilator weaning predictor Children
  • 相关文献

参考文献28

  • 1Newth C J,Venkataraman S,Willson DF. Weaning and extubation readiness in pediatric patients[J].Pediatric Critical Care Medicine,2009,(01):1-11.
  • 2Kulkarni AP,Agarwal V. Extubation failure in intensive care unit:predictors and management[J].INDIAN JOURNAL OF CRITICAL CARE MEDICINE,2008,(01):1-9.
  • 3El-Khatib MF,Bou-Khalil P. Clinical review:liberation from mechanical ventilation[J].CRITICAL CARE,2008,(04):221.
  • 4Mauri T,Pivi S,Bigatello LM. Prolonged mechanical ventilation after critical illness[J].Minerva Anestesiologica,2008,(06):297-301.
  • 5MacIntyre NR,Cook D J,Ely EW Jr. Evidence-based guidelines for weaning and discontinuing ventilatory support:a collective task force facilitated by the American College of Chest Physicians;the American Association for Respiratory Care;and the American College of Critical Care Medicine[J].CHEST,2001,(6 Suppl):375S-395S.
  • 6鲍滨.机械通气撤离的研究进展[J].医学综述,2008,14(12):1858-1860. 被引量:7
  • 7Robertson TE,Sona C,Schallom L. Improved extubation rates and earlier liberation from mechanical ventilation with implementation of a daily spontaneous-breathing trial protocol[J].Journal of the American College of Surgeons,2008,(03):489-495.
  • 8罗祖金,詹庆元,孙兵,王辰.自主呼吸试验的操作与临床应用[J].中国呼吸与危重监护杂志,2006,5(1):60-62. 被引量:59
  • 9Cabello B,Thille AW,Roche-Campo F. Physiological comparison of three spontaneous breathing trials in difficult-towean patients[J].Intensive Care Medicine,2010,(07):1171-1179.
  • 10Yang KL,Tobin MJ. A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation[J].New England Journal of Medicine,1991,(21):1445-1450.

二级参考文献65

共引文献83

同被引文献20

  • 1Kiserud T, Ebbing C, Kessler J, et al. Fetal cardiac output, distribution to the placenta and impact of placental compromise [ J ]. Ultrasound Obstet Gyneco1,2006,28 (2) : 126 - 136.
  • 2Charles S, Kleinman, Istvan Seri. Hemodynamics and Cardiology [ M ]. 2"d ed. New York : Saunders ,2012 :4 -6.
  • 3He SR, Sun X, Zhang C, et al. Measurement of systemic oxygen delivery and inotropy in healthy term neonates with the ultrasonic cardiac output monitor ( USCOM ) [ J ]. Early Hum Dev, 2013,89 ( 5 ) :289 - 294.
  • 4EI-Khuffash AF, McNamara PJ. Neonatologist-performed functional echo- cardiography in the neonatal intensive care unit [ J ]. Semin Fetal Neonatal Med,2011,16( 1 ) :50 -60.
  • 5Heuchan AM, Clyman RI. Managing the patent ductus arteriosus:current treatment options[ J]. Arch Dis Child Fetal Neonatal Ed ,2014,99(5 ) : F431 - Fg36.
  • 6Bland JM, Altman DG. Agreed statistics:measurement method compari- son [ J ]. Anesthesiology,2012,116 ( 1 ) : 182 - 185.
  • 7Chong SW,Peyton PJ. A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor ( USCOM ) [ J ]. Anaesthesia, 2012,67 ( 11 ) : 1266 - 1271.
  • 8Gopal S, Do T, Pooni JS, et al. Validation of cardiac output studies from the Mostcare compared to a pulmonary artery catheter in septic patients [J]. Minerva Anestesiol,2014,80(3) :314 -323.
  • 9Wongsirimetheekul T, Khositseth A, Lertbunrian R. Non-invasive cardiac output assessment in critically ill paediatrie patients[ J ]. Acta Cardiol, 2014,69(2) :167 - 173.
  • 10Horster S, Stemmler HJ, Sparrer JA, et al. Mechanical ventilation with positive end-expiratory pressure in critically ill patients:comparison of CW-Doppler ultrasound cardiac output monitoring (USCOM) and ther- modilution (PiCCO) [J]. Acta Cardiol,2012,67(2) :177 - 185.