摘要
目的建立油炸面制品中苯并(a)芘的测定方法。方法样品经石油醚(沸程30℃~60℃)浸提油脂,乙酸乙酯+环己烷(1:1)溶解,凝胶色谱(GPC)净化,溶剂转换浓缩后采用高效液相色谱法C18柱分离,以乙腈:水(95:5)作为流动相,流速1.0ml/min,检测器激发波长290nm、发射波长430nm进行检测,外标法定量。结果苯并(a)芘标准曲线在0.10—10.0μg/L范围内呈线性关系,r=0.999,回收率为90.0%-93.7%,相对标准偏差(RSD)均小于4%,方法检出限0.1μg/kg。结论该测定方法具有前处理简单、快速、准确、灵敏度高等优点,可适用于油炸面制品样品苯并(a)芘的测定。
Objective To establish the determination method of the benzo (a) pyrene in the fried flour products. Methods Samples were extracted with petroleum ether ( boiling range of 30℃~60℃ ) , were dissolved by the ethyl acetate + cyclohexane ( 1 : 1 ) and purified by gel permeation chromatography (GPC) . After con- centration, the sample was assayed by the high -performance liquid chromatography under the special condi- tions which include C18 column, mobile phase of acetonitrile - water (95: 5) , flow rate 1.0ml/min, excita- tion wavelength 290nm and emission wavelength of 430nm for detection, external standard method of quantita- tive Results BaP standard curve in 0. 10 - 10. 0μg / L range was linear, r = 0. 999, the recovery was 90. 0% - 93.7%, RSD of the method was less than 4%, the detection limit was 0. 1μg/kg. Conclusions The method is simple, fast, accurate, high sensitivity and suitable for determination of BaP in the fried flour products.
出处
《医学动物防制》
2014年第2期221-224,共4页
Journal of Medical Pest Control
关键词
苯并(A)芘
凝胶渗透色谱
高效液相色谱
油炸面制品
Benzo (a) pyrene
Gel permeation chromatography
High Performance Liquid Chromatography
Fried flour products