Measurement of X-ray photon energy and arrival time using a silicon drift detector 被引量:1

Measurement of X-ray photon energy and arrival time using a silicon drift detector
原文传递
导出
摘要 Detecting the X-ray emission of pulsars and obtaining the photons' time of arrival are the foundational steps in autonomous navigation via X-ray pulsar measurement.The precision of a pulse's time of arrival is mainly determined by the precision of photon arrival time measurement.In this work,a silicon drift detector is used to measure photon energy and arrival time.The measurement system consists of a signal detector,a processing unit,a signal acquisition unit and a data receiving unit.This system acquires the energy resolution and arrival time information of photons.In particular,background noise with different energies disturbs pulse profile forming,the system can also achieve a high signal-to-noise ratio profile.Ground test results show that this system can be applied in autonomous navigation based on X-ray pulsar measurement. Detecting the X-ray emission of pulsars and obtaining the photons' time of arrival are the foundational steps in autonomous navigation via X-ray pulsar measurement.The precision of a pulse's time of arrival is mainly determined by the precision of photon arrival time measurement.In this work,a silicon drift detector is used to measure photon energy and arrival time.The measurement system consists of a signal detector,a processing unit,a signal acquisition unit and a data receiving unit.This system acquires the energy resolution and arrival time information of photons.In particular,background noise with different energies disturbs pulse profile forming,the system can also achieve a high signal-to-noise ratio profile.Ground test results show that this system can be applied in autonomous navigation based on X-ray pulsar measurement.
出处 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期39-44,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(10973048)
关键词 X-ray photon energy time of arrival detector X-ray photon energy time of arrival detector
  • 相关文献

参考文献10

  • 1Voges W, Aschenbach B, Boner T et al. ROSAT All-sky Survey Faint Source Catalogue. International Astronomical Union Circular, 2000, 7432.
  • 2Sheikh S I, Pines J D. Journal of Guidance, Control, and Dynamics, 2006, 19: 49-63.
  • 3Emadzadeh A A, Speye J L, Hadaegh F Y. A Parametric Study of Relative Navigation using Pulsars. Proceedings of ION 63rd Annual Meeting Cambridge, USA. 2007.
  • 4Graven P H, Collins J T, Suneel I S et al. Spacecraft Aviation Using X-Ray Pulsars. 7th International ESA Conference on Guidance, Navigation & Control Systems. County Kerry, Ireland, 2008.
  • 5Wood K S, Determan J R, Ray P S et al. Using the Unconven-tional Stellar Aspect (USA) Experiment on ARGOS to Determine Atmospheric Parameters by X-ray Occultation. Proceedings of SPIE- The International Society for Optical Engineering. USA: SPIE, 2002.
  • 6HU Hui-Jun, ZHAO Bao-Sheng, Acta Phys. Sin., 2012, 61(1): 1-7.
  • 7ZHANG Fei, WANG Huan-Yu, PENG Wen-Xi et al, CPC (HEP & NP), 2012, 36(2): 146-150.
  • 8Lechner P, Eckbauer S, Hartmann R et al, Nuclear Instruments and Methods in Physics Research, 1996, 377: 346-351.
  • 9Nouais D, Beole S, Bondila M et al. Nuclear Instruments and Methods in Physics Research, 2003, 501: 119-125.
  • 10ZHENG Wei, SUN Shou-Ming. China Patent, ZL201010022035.7 2012.